Melatonin reduces night blood pressure in patients with nocturnal hypertension
Abstract
Purpose Nocturnal hypertension is associated with a high risk of morbidity and mortality. A blunted nocturnal surge in melatonin excretion has been described in nondipping hypertensive patients. We therefore studied the potency of melatonin to reduce nighttime blood pressure (BP) in treated hypertensive patients with nocturnal hypertension.Patients and methods Thirty-eight treated hypertensive patients (22 males, mean age 64+/-11 years) with confirmed nocturnal hypertension (mean nighttime systolic BP >125 mm Hg), according to repeated 24-hour ambulatory blood pressure monitoring (ABPM), were randomized in a double-blind fashion to receive either controlled release (CR)-melatonin 2 mg or placebo 2 hours before bedtime for 4 weeks. A 24-hour ABPM was then performed.Results Melatonin treatment reduced nocturnal systolic BP significantly from 136+/-9 to 130+/-10 mm Hg (P=.011), and diastolic BP from 72+/-11 to 69+/-9 mm Hg (P=.002), whereas placebo had no effect on nocturnal BP. The reduction in nocturnal systolic BP was significantly greater with melatonin than with placebo (P=.01), and was most prominent between 2:00 AM and 5:00 AM (P=.002).Conclusions Evening CR-melatonin 2 mg treatment for 4 weeks significantly reduced nocturnal systolic BP in patients with nocturnal hypertension. Thus, an addition of melatonin 2 mg at night to stable antihypertensive treatment may improve nocturnal BP control in treated patients with nocturnal hypertension.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The blood pressure lowering effect of melatonin after repeated administration in hypertensive patients has been replicated by others.
“The blood pressure lowering effect of melatonin after repeated administration in hypertensive patients has been replicated by others (Cagnacci et al., 2005; Grossman et al., 2006).”
From The impact of the circadian timing system on cardiovascular and metabolic function (2012) · cites this paper as Grossman et al., 2006
The citation lists haven’t been fetched yet
References 10 · Cited by 168
- Authors
- Grossman, E., Laudon, M., Yalcin, R., Zengil, H., Peleg, E., Sharabi, Y., Kamari, Y., Shen-Orr, Z., & Zisapel, N.
- Affiliations
- Tel Aviv University (IL)
- Neurim Pharmaceuticals (Israel) (IL)
- Gazi University (TR)
- Corresponding author
- Grossman, Ehud
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2006-10
- Volume
- 119
- Issue
- 10
- Pages
- 898-902
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W2049635596
- Cited by
- 168
- References
- 10
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 9 · 2023: 8 · 2022: 10 · 2021: 7 · 2020: 5 · 2019: 12 · 2018: 13 · 2017: 6 · 2016: 11 · 2015: 7 · 2014: 15 · 2013: 10 · 2012: 12
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The American Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- melatonin, nocturnal hypertension, nocturnal blood pressure, antihypertensive therapy, ambulatory blood pressure monitoring
- MeSH terms
- Adult, Aged, Aged, 80 and over, Antihypertensive Agents, Circadian Rhythm, Delayed-Action Preparations, Double-Blind Method, Female, Humans, Hypertension, Male, Melatonin, Middle Aged, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review