Mortality Associated with Low Serum Sodium Concentration in Maintenance Hemodialysis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND Low serum sodium concentrations are associated with an increased risk of death in the general population, but causality is uncertain due to confounding from clinical conditions such as congestive heart failure and cirrhosis, in which hyponatremia results from elevated levels of arginine vasopressin. METHODS To examine the association between predialysis serum sodium concentration and mortality in patients undergoing hemodialysis for end-stage renal disease, a condition in which arginine vasopressin does not affect water excretion and osmoregulation, we studied 1549 oligoanuric participants in the HEMO study, a randomized controlled trial of hemodialysis patients examining the effect of hemodialysis dose and flux. We used proportional hazards models to compare the risk of death according to predialysis serum sodium concentration. RESULTS Considered as a continuous variable, each 4-mEq/L increment in baseline predialysis serum sodium concentration was associated with a hazard ratio for all-cause mortality of 0.84 (95% confidence interval (CI), 0.78–0.90). Multivariable adjustment for demographic, clinical, laboratory, and dialysis-specific covariates, including ultrafiltration volume, did not appreciably change the results (hazard ratio for all-cause mortality of 0.89; 95% CI, 0.82–0.96). The results also were consistent in time-updated analyses using repeated measures of serum sodium and other relevant covariates. CONCLUSION Lower predialysis serum sodium concentration is associated with an increased risk of death. Considering the unique physiology in the dialysis population, these findings raise the possibility that hyponatremia itself may be a causal determinant of mortality in the broader population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inappropriate use of bivariable analysis to screen risk factors for use in multivariable analysis
Sun, G.-W., Shook, T. L., & Kay, G. L. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(96)00025-x · Cited by 933
Cited by
Kovesdy, C. P., Lott, E. H., Lu, J. L., Malakauskas, S. M., Ma, J. Z., Molnar, M. Z., & Kalantar-Zadeh, K. (2012) · Circulation · doi:10.1161/circulationaha.111.065391 · Cited by 298
Palmer, S. C., Natale, P., Ruospo, M., Saglimbene, V. M., Rabindranath, K. S., Craig, J. C., & Strippoli, G. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004541.pub3 · Cited by 96
Metadata
- Authors
- Waikar, S. S., Curhan, G. C., & Brunelli, S. M.
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 124
- Issue
- 1
- Pages
- 77-84
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W2094810295
- Cited by
- 165
- References
- 1
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mortality Associated with Low Serum Sodium Concentration in Maintenance Hemodialysis. https://app.cochat.ai/papers/10.1016/j.amjmed.2010.07.029
- The paper
- Waikar, S. S., Curhan, G. C., & Brunelli, S. M. (2011). Mortality Associated with Low Serum Sodium Concentration in Maintenance Hemodialysis. The American Journal of Medicine. https://doi.org/10.1016/j.amjmed.2010.07.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).