Will Patients “Opt In” to Perform Their Own Rapid HIV Test in the Emergency Department?

Open access
Gaydos, Charlotte A., Hsieh, Yu-Hsiang, Harvey, Leah, Burah, Avanti, Won, Helen, Jett-Goheen, Mary, Barnes, Mathilda, Agreda, Patricia, Arora, Nick, Rothman, Richard E. · 2011 · Annals of Emergency Medicine
Cited by 80

The DOI matches its Crossref record.

Abstract

Objective To evaluate the feasibility and accuracy of existing point-of-care (POC) HIV tests performed by an untrained patient compared to the routinely used HIV POC test offered to patients in two urban emergency departments (ED). Methods From April 2008 through December 2009, patients, who had completed a standard HIV oral fluid test performed by a trained healthcare professional and who were unaware of their results, were recruited to perform a rapid POC HIV test. Patients were given a choice of the oral fluid or the finger-stick blood POC. Evaluation of acceptability to perform the mechanics of the test was accessed by questionnaire. For the “self-test,” the participant obtained his/her own sample and performed the test. The patient’s results were compared to standard oral fluid results obtained by the health care professional. Results Overall, 478 of 564 (85%) patients receiving a standard oral fluid HIV test volunteered, with a mean age of 38–39 years. Ninety-one percent of participants chose oral fluid and 9% chose blood (p<0.05). Self-test results were 99.6% concordant with health care professionals’ test results. For the self-testers, 94% of oral fluid testers and 84.4% of blood testers reported trusting the self-administered test result “very much.” Furthermore, 95.6% of oral fluid group and 93.3% of the blood group would “probably” or “definitely” perform a test at home, if available. Conclusions This study demonstrated that a significant proportion of patients offered a self-HIV POC volunteered and preferred using oral fluid. Patients’ results agreed with standard HIV POC results. The majority of participants trusted their results and would perform a POC HIV test at home, given the opportunity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.annemergmed.2011.03.029

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 80

Metadata

Authors
Gaydos, C. A., Hsieh, Y.-H., Harvey, L., Burah, A., Won, H., Jett-Goheen, M., Barnes, M., Agreda, P., Arora, N., & Rothman, R. E.
Venue
Annals of Emergency Medicine
Publisher
Elsevier BV
Published
2011-07
Volume
58
Issue
1
Pages
S74-S78
ISSN
0196-0644 (ISSN-L)
OpenAlex
W2166675378
Cited by
80
References
0
FWCI
5.41
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Will Patients “Opt In” to Perform Their Own Rapid HIV Test in the Emergency Department? https://app.cochat.ai/papers/10.1016/j.annemergmed.2011.03.029
The paper
Gaydos, C. A., Hsieh, Y.-H., Harvey, L., Burah, A., Won, H., Jett-Goheen, M., Barnes, M., Agreda, P., Arora, N., & Rothman, R. E. (2011). Will Patients “Opt In” to Perform Their Own Rapid HIV Test in the Emergency Department? Annals of Emergency Medicine. https://doi.org/10.1016/j.annemergmed.2011.03.029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.