CoChat

Ultralong Versus Standard Long Peripheral Intravenous Catheters: A Randomized Controlled Trial of Ultrasonographically Guided Catheter Survival

Open access
Bahl, Amit, Hijazi, Mahmoud, Chen, Nai-Wei, Lachapelle-Clavette, Ludovic, Price, Jacob · 2020 · Annals of Emergency Medicine
Cited by 63

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVE Ultrasonographically guided intravenous peripheral catheters have dismal dwell time, with most intravenous lines failing before completion of therapy. Catheter length in the vein is directly related to catheter longevity. We investigate the survival of an ultralong ultrasonographically guided intravenous peripheral catheter compared with a standard long one. METHODS We conducted a single-site, nonblinded, randomized trial of catheter survival. Adult patients presenting to the emergency department with difficult vascular access were recruited and randomized to receive either standard long, 4.78-cm, 20-gauge ultrasonographically guided intravenous peripheral catheters or ultralong, 6.35-cm, 20-gauge ultrasonographically guided intravenous peripheral catheters. The primary outcome was duration of catheter survival. The secondary outcome was the optimal length of the catheter in the vein to maximize survival. Additional intravenous-related endpoints included first-stick success, time to insertion, number of attempts, thrombosis, and infection. RESULTS Between October 2018 and March 2019, 257 patients were randomized, with 126 in the standard long ultrasonographically guided intravenous peripheral catheter group and 131 in the ultralong group. Kaplan-Meier estimate of catheter median survival time in the ultralong group was 136 hours (95% confidence interval [CI] 116 to 311 hours) compared with 92 hours (95% CI 71 to 120 hours) in the standard long group, for a difference of 44 hours (95% CI 2 to 218 hours). The optimal catheter length in the vein was 2.75 cm, and intravenous lines with greater than 2.75 cm inserted had a median survival of 129 hours (95% CI 102 to 202 hours) compared with 75 hours (95% CI 52 to 116 hours) for intravenous lines with less than or equal to 2.75 cm, for a difference of 54 hours (95% CI 10 to 134 hours). Insertion characteristics were similar between the groups: 74.1% versus 79.4% first-stick success (95% CI for the difference -2% to 5%), 1.4 versus 1.3 for number of attempts (95% CI for the difference -0.1 to 0.3), and 6.9 versus 5.9 minutes to completion (95% CI for the difference -1.3 to 3.4) with ultralong versus standard long, respectively. There were no cases of infection or thrombosis. CONCLUSION This study demonstrated increased catheter survival when the ultralong compared with the standard long ultrasonographically guided intravenous peripheral catheter was used, whereas insertion characteristics and safety appeared similar.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.annemergmed.2019.11.013

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 63

Metadata

Authors
Bahl, A., Hijazi, M., Chen, N.-W., Lachapelle-Clavette, L., & Price, J.
Venue
Annals of Emergency Medicine
Publisher
Elsevier BV
Published
2020-08
Volume
76
Issue
2
Pages
134-142
ISSN
0196-0644 (ISSN-L)
OpenAlex
W2999395293
Cited by
63
References
3
FWCI
6.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultralong Versus Standard Long Peripheral Intravenous Catheters: A Randomized Controlled Trial of Ultrasonographically Guided Catheter Survival. https://app.cochat.ai/papers/10.1016/j.annemergmed.2019.11.013
The paper
Bahl, A., Hijazi, M., Chen, N.-W., Lachapelle-Clavette, L., & Price, J. (2020). Ultralong Versus Standard Long Peripheral Intravenous Catheters: A Randomized Controlled Trial of Ultrasonographically Guided Catheter Survival. Annals of Emergency Medicine. https://doi.org/10.1016/j.annemergmed.2019.11.013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.