Fault diagnosis of angle grinders and electric impact drills using acoustic signals
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Abstract Electric motors use about 68% of total generated electricity. Fault diagnosis of electrical motors is an important task, because it allows saving a large amount of money and time. An analysis of acoustic signals is a promising tool to improve the accuracy of fault diagnosis. It is essential to analyze acoustic signals to assess the state of the motor. In this paper, three electric impact drills (EID) were analyzed using acoustic signals: healthy EID, EID with damaged rear bearing, EID with damaged front bearing. Three angle grinders (AG) were analyzed: healthy AG, AG with 1 blocked air inlet, AG with 2 blocked air inlets. The authors proposed a method for feature extraction: SMOFS-NFC (Shortened Method of Frequencies Selection Nearest Frequency Components). Acoustic features vectors were classified by the nearest neighbor classifier and Naive Bayes classifier. The classification accuracy were in the range of 89.33–97.33% for three electric impact drills. The classification accuracy were in the range of 90.66–100% for three angle grinders. The presented method is very useful for diagnosis of bearings, ventilation faults and other mechanical faults of power tools. It can be also useful for diagnosis of similar power tools.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Mechanical fault diagnosis using Convolutional Neural Networks and Extreme Learning Machine
Chen, Z., Gryllias, K., & Li, W. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.106272 · Cited by 390
Fault diagnosis of single-phase induction motor based on acoustic signals
Glowacz, A. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.07.044 · Cited by 351
Self-citationZhang, Y., Chen, B., Pan, G., & Zhao, Y. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.05.005 · Cited by 276
Fault diagnosis of electric impact drills using thermal imaging
Głowacz, A. (2020) · Measurement · doi:10.1016/j.measurement.2020.108815 · Cited by 229
Zhang, D., Stewart, E., Entezami, M., Roberts, C., & Yu, D. (2020) · Measurement · doi:10.1016/j.measurement.2020.107585 · Cited by 222
Duan, Z., Wu, T., Guo, S., Shao, T., Malekian, R., & Li, Z. (2018) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-017-1474-8 · Cited by 196
Sounds and acoustic emission-based early fault diagnosis of induction motor: A review study
AlShorman, O., Alkahatni, F., Masadeh, M., Irfan, M., Glowacz, A., Althobiani, F., Kozik, J., & Glowacz, W. (2021) · Advances in Mechanical Engineering · doi:10.1177/1687814021996915 · Cited by 186
Self-citationAn Approach on MCSA-Based Fault Detection Using Independent Component Analysis and Neural Networks
Garcia-Bracamonte, J. E., Ramírez-Cortés, J. M., Rangel‐Magdaleno, J., Gómez‐Gil, P., Barreto, H. P., & Alarcon‐Aquino, V. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2900143 · Cited by 134
A Rotating Machinery Fault Diagnosis Method Based on Feature Learning of Thermal Images
Jia, Z. Y., Liu, Z., Vong, C., & PECHT, M. G. (2019) · IEEE Access · doi:10.1109/access.2019.2893331 · Cited by 125
Cited by
Diagnosisformer: An efficient rolling bearing fault diagnosis method based on improved Transformer
Hou, Y., Wang, J., Chen, Z., Ma, J., & Li, T. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2023.106507 · Cited by 321
Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review
Mohd Ghazali, M. H., & Rahiman, W. (2021) · Shock and Vibration · doi:10.1155/2021/9469318 · Cited by 249
“Real-time machine monitoring can be achieved using vibration analysis and there are many well-developed signal processing techniques that can be applied. limitations of vibration analysis are noise contamination and proper mounting position of the vibration sensors [6].”
GTFE-Net: A Gramian Time Frequency Enhancement CNN for bearing fault diagnosis
Jia, L., Chow, T. W. S., & Yuan, Y. (2023) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105794 · Cited by 188
Roy, A. M. (2022) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105347 · Cited by 183
Ventilation Diagnosis of Angle Grinder Using Thermal Imaging
Glowacz, A. (2021) · Sensors · doi:10.3390/s21082853 · Cited by 165
Self-citation
Metadata
- Authors
- Glowacz, A., Tadeusiewicz, R., Legutko, S., Caesarendra, W., Irfan, M., Liu, H., Brumercik, F., Gutten, M., Sulowicz, M., Antonino Daviu, J. A., Sarkodie-Gyan, T., Fracz, P., Kumar, A., & Xiang, J.
- Venue
- Applied Acoustics
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 179
- Pages
- 108070
- ISSN
- 0003-682X (ISSN-L)
- OpenAlex
- W3156676812
- Cited by
- 178
- References
- 37
- FWCI
- 17.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.