The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Peroxymonosulfate-enhanced visible light photocatalytic degradation of bisphenol A by perylene imide-modified g-C3N4
Abstract
In this study, a metal-free photocatalyst (PI-g-C3N4) was synthesized through an amidation reaction between perylene tetracarboxylic dianhydride (PTCDA) and graphitic carbon nitride (g-C3N4). In order to enhance the photocatalytic degradation efficiency of bisphenol A (BPA) by 5 wt% PI-g-C3N4, peroxymonosulfate (PMS) was introduced into this system. When 5 mM PMS was added, 96% of BPA with an initial concentration of 10 mg/L was degraded within 60 min; the pseudo-first-order degradation kinetics constant of BPA was increased from 0.0057 to 0.0501 min−1. Based on the photoelectrochemical analysis, it was proposed that PI-g-C3N4 achieved a more effective separation of photogenerated electron–hole pairs and displayed higher conductivity than PTCDA and g-C3N4 individually, thus promoting the PMS activation into active radicals by the photogenerated electrons. The BPA degradation was favored at high PMS concentrations under alkaline conditions. The slight inhibition effect of co-existing anions on the degradation of BPA followed the order: H2PO4− > NO3− ≈ HCO3−; Cl− had a remarkable positive effect on the degradation of BPA. The radical quenching tests and electron spin resonance results indicated that O2 −, 1O2, and h+ were the major species for the degradation of BPA. Combined with intermediates analysis, the degradation mechanism and pathway of BPA was proposed. The high stability of the 5 wt% PI-g-C3N4 was finally demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Graphene Oxide for Catalytic Oxidation of Aqueous Organic Pollutants
Sun, H., Liu, S., Zhou, G., Ang, H. M., Tadé, M. O., & Wang, S. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am301372d · Cited by 722
Cited by
Chen, F., Huang, G.-X., Yao, F.-B., Yang, Q., Zheng, Y.-M., Zhao, Q.-B., & Yu, H.-Q. (2020) · Water Research · doi:10.1016/j.watres.2020.115559 · Cited by 459
Hasija, V., Nguyen, V.-H., Kumar, A., Raizada, P., Krishnan, V., Khan, A. A. P., Singh, P., Lichtfouse, E., Wang, C., & Thi Huong, P. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125324 · Cited by 453
Wang, X., Meng, J., Zhang, X., Liu, Y., Ren, M., Yang, Y., & Guo, Y. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010763 · Cited by 285
Zhou, X., Luo, C., Luo, M., Wang, Q., Wang, J., Liao, Z., Chen, Z., & Chen, Z. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.122587 · Cited by 280
Wang, R.-Z., Huang, D.-L., Liu, Y.-G., Zhang, C., Lai, C., Wang, X., Zeng, G.-M., Gong, X.-M., Duan, A., Zhang, Q., et al. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.04.071 · Cited by 279
Metadata
- Authors
- Zhang, J., Zhao, X., Wang, Y., Gong, Y., Cao, D., & Qiao, M.
- Venue
- Applied Catalysis B: Environmental
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 237
- Pages
- 976-985
- ISSN
- 0926-3373 (ISSN-L)
- OpenAlex
- W2808802259
- Cited by
- 234
- References
- 1
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.