Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 215

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Enhanced photocatalytic ozonation of organic pollutants using an iron-based metal-organic framework

Yu, Deyou, Li, Lubiao, Wu, Minghua, Crittenden, John C. · 2019 · Applied Catalysis B: Environmental

Abstract

The photocatalytic activity of metal-organic frameworks (MOFs) is drawing great attention in the field of environmental remediation. However, the efficiency of MOFs still remains low because of the rapid recombination of valence band holes and conduction band electrons (a.k.a., charge carriers). The combination of photocatalysis and electron acceptors such as ozone are believed to be an efficient strategy to reduce the charge carrier recombination. Herein, we report that photocatalytic ozonation (PCO) using an Fe-based MOF (MIL-88A(Fe)) has greater destruction than photocatalysis and/or catalytic ozonation in terms of 4-nitrophenol (4-NP) degradation and mineralization. It is worth noting that our Fe-based MOF has a large number of Lewis acid sites (LAS). The pseudo-first order kinetic rate constants (k) of 4-NP degradation using PCO, photocatalysis and catalytic ozonation systems are 0.1632, 0.0143 and 0.0840 min−1, respectively. The TOC removal of 4-NP in the PCO system is approximately 75.4% ([4-NP] = 100 ppm, ozone input dosage = 1.5 mg/min-L, UV light intensity = 3.46 × 10-6 Einstiens/L-s, treatment time = 30 min) and this is much greater than those of photocatalysis (17.6%) and catalytic ozonation (38.7%). Most importantly, both the k value and TOC removal in the PCO system are much higher than the sum of those in other two processes, implying a strong synergistic effect in the PCO process. Mechanistic studies were conducted using electrochemical impedance spectroscopy (EIS) and photoluminescence (PL) measurements and demonstrate that the synergistic effect may originate from the enhanced photoinduced carrier separation using ozone as an electron acceptor. Furthermore, OH, O2−, and 1O2 are found to be the principal reactive oxygen species (ROS) for 4-NP degradation and mineralization. Integrating the analysis of band structure, EPR and scavenging experiment results, ozone is not only able to reduce charge carrier recombination but also can be catalytically decomposed to generate more ROS on the LAS of MIL-88A(Fe). This study provides deep insights into the use of MOFs as effective advanced oxidation processes (AOPs).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apcatb.2019.03.050

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
Yu, D., Li, L., Wu, M., & Crittenden, J. C.
Venue
Applied Catalysis B: Environmental
Publisher
Elsevier BV
Published
2019-08
Volume
251
Pages
66-75
ISSN
0926-3373 (ISSN-L)
OpenAlex
W2924821390
Cited by
215
References
3
FWCI
9.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.