Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 248

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Accelerating Fe(Ⅲ)/Fe(Ⅱ) cycle via Fe(Ⅱ) substitution for enhancing Fenton-like performance of Fe-MOFs

Yang, Taoyu, Yu, Deyou, Wang, Dong, Yang, Tao, Li, Zexiong, Wu, Minghua, Petru, Michal, Crittenden, John · 2021 · Applied Catalysis B: Environmental

Abstract

Abstract Metal-organic frameworks (MOFs), especially iron-based MOFs (Fe-MOFs), are deemed as promising Fenton-like catalysts due to their well-developed pores and accessible active sites. However, the Fenton-like performance of Fe-MOFs is limited by the relatively low redox rate of Fe(Ⅲ)/Fe(Ⅱ) couples and density of coordinatively unsaturated iron centers (CUICs), which depend on the intrinsic structure of iron-oxo nodes in Fe-MOFs. Herein, we manipulated the structure of iron-oxo nodes in MIL-53(Fe) via a Fe(Ⅱ) substitution method, affording a mixed-valence (i.e., Fe(Ⅱ)/Fe(Ⅲ)) material (denoted as FeⅡ-MIL-53(Fe)) with highly improved Fenton-like performance. The substituted Fe(Ⅱ) centers could serve as stronger active sites, where Fe(Ⅱ)→Fe(Ⅲ) half-reaction occurs, over original Fe(Ⅲ) centers to rapidly activate H2O2 for efficient destruction of 4-nitrophenol (4-NP). Meanwhile, Fe(Ⅱ) substitution induced the formation of a larger amount of Fe(Ⅲ) CUICs, which was proven by the increased Lewis acidity of MIL-53(Fe). The increased density of Fe(Ⅲ) CUICs promoted the interaction between Fe(Ⅲ) centers and H2O2 and thus rendered another half-reaction, Fe(Ⅲ)→Fe(Ⅱ), with a greater rate. Accordingly, the accelerated cycle of Fe(Ⅲ)/Fe(Ⅱ) couples favored OH generation for improving 4-NP degradation. As a result, the 4-NP degradation and rate on FeⅡ-MIL-53(Fe) were 1.39 and 9.48 times higher than that on pristine MIL-53(Fe). Moreover, FeⅡ-MIL-53(Fe) showed a good stability and reusability over multiple cycles. Our work provides insights into the rational design of Fe-MOFs as promising Fenton-like catalysts for advanced water/wastewater treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apcatb.2020.119859

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 248

Metadata

Authors
Yang, T., Yu, D., Wang, D., Yang, T., Li, Z., Wu, M., Petru, M., & Crittenden, J.
Venue
Applied Catalysis B: Environmental
Publisher
Elsevier BV
Published
2021-06
Volume
286
Pages
119859
ISSN
0926-3373 (ISSN-L)
OpenAlex
W3117944686
Cited by
248
References
1
FWCI
9.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accelerating Fe(Ⅲ)/Fe(Ⅱ) cycle via Fe(Ⅱ) substitution for enhancing Fenton-like performance of Fe-MOFs. https://app.cochat.ai/papers/10.1016/j.apcatb.2020.119859
The paper
Yang, T., Yu, D., Wang, D., Yang, T., Li, Z., Wu, M., Petru, M., & Crittenden, J. (2021). Accelerating Fe(Ⅲ)/Fe(Ⅱ) cycle via Fe(Ⅱ) substitution for enhancing Fenton-like performance of Fe-MOFs. Applied Catalysis B: Environmental. https://doi.org/10.1016/j.apcatb.2020.119859

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.