Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 342

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Impact of the level of temporal and operational detail in energy-system planning models

Open access
Poncelet, Kris, Delarue, Erik, Six, Daan, Duerinck, Jan, D’haeseleer, William · 2016 · Applied Energy

Abstract

To limit the computational cost, bottom-up long-term (LT) energy-system planning models typically have a stylized temporal representation and do not consider techno-economic operational constraints of power plants. Both these simplifications have been shown to have a significant impact on the results. However, increasing the level of temporal and techno-economic operational detail will result in an increased computational cost. In this regard, the first goal of this work is to quantify which of these simplifications has the highest impact on the results, and should therefore be prioritized for improving. To do so, the impact of both the low level of temporal and techno-economic operational detail are quantified for a varying penetration of intermittent renewable energy sources (IRES). For a high penetration of IRES, the gains obtained by improving the temporal representation are shown to outweigh the gains obtained by incorporating detailed techno-economic operational constraints. Therefore, improving the temporal representation is suggested to be prioritized. The second goal of this paper is to identify opportunities for model improvements. Different approaches to improve the temporal representation are proposed. While the focus in the literature lies primarily on the impact of the temporal resolution, this work more fundamentally considers and assesses different approaches of dealing with the temporal dimension. Using a different approach of defining the time slices to explicitly account for IRES variability is found to lead to a higher accuracy than can be obtained by simply increasing the temporal resolution, while requiring a lower number of time slices. Moreover, a temporal representation based on selecting a set of representative days can achieve an even higher accuracy, albeit requiring a higher number of time slices. An additional advantage of using representative days is that chronology is retained such that the impact of short-term dynamic fluctuations of IRES can be accounted for.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2015.10.100

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 342

Metadata

Authors
Poncelet, K., Delarue, E., Six, D., Duerinck, J., & D’haeseleer, W.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2016-01
Volume
162
Pages
631-643
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2170076688
Cited by
342
References
20
FWCI
8.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of the level of temporal and operational detail in energy-system planning models. https://app.cochat.ai/papers/10.1016/j.apenergy.2015.10.100
The paper
Poncelet, K., Delarue, E., Six, D., Duerinck, J., & D’haeseleer, W. (2016). Impact of the level of temporal and operational detail in energy-system planning models. Applied Energy. https://doi.org/10.1016/j.apenergy.2015.10.100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.