Effect of tariffs on the performance and economic benefits of PV-coupled battery systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The use of batteries in combination with PV systems in single homes is expected to become a widely applied energy storage solution. Since PV system cost is decreasing and the electricity market is constantly evolving there is marked interest in understanding the performance and economic benefits of adding battery systems to PV generation under different retail tariffs. The performance of lead-acid (PbA) and lithium-ion (Li-ion) battery systems in combination with PV generation for a single home in Switzerland is studied using a time-dependant analysis. Firstly, the economic benefits of the two battery types are analysed for three different types of tariffs, i.e. a dynamic tariff based on the wholesale market (one price per hour for every day of the year), a flat rate and time-of-use tariff with two periods. Secondly, the reduction of battery capacity and annual discharge throughout the battery lifetime are simulated for PbA and Li-ion batteries. It was found that despite the levelised value of battery systems reaches up to 28% higher values with the dynamic tariff compared to the flat rate tariff, the levelised cost increases by 94% for the dynamic tariff, resulting in lower profitability. The main reason for this is the reduction of equivalent full cycles performed with by battery systems with the dynamic tariff. Economic benefits also depend on the regulatory context and Li-ion battery systems were able to achieve internal rate of return (IRR) up to 0.8% and 4.3% in the region of Jura (Switzerland) and Germany due to higher retail electricity prices (0.25CHF/kWh and 0.35CHF/kWh respectively) compared to Geneva (0.22CHF/kWh) where the maximum IRR was equal to −0.2%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accurate electrical battery model capable of predicting runtime and I-V performance
Chen, M., & Rincon-Mora, G. A. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874229 · Cited by 2,427
Cited by
An interdisciplinary review of energy storage for communities: Challenges and perspectives
Parra, D., Swierczynski, M., Stroe, D. I., Norman, S. A., Abdon, A., Worlitschek, J., O’Doherty, T., Rodrigues, L., Gillott, M., Zhang, X., et al. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.003 · Cited by 307
Self-citationLiu, J., Chen, X., Cao, S., & Yang, H. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.02.080 · Cited by 268
An integrated techno-economic and life cycle environmental assessment of power-to-gas systems
Parra, D., Zhang, X., Bauer, C., & Patel, M. K. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.02.063 · Cited by 251
“Australia [60], P2G could bring more economic benefits at the grid-scale level (i.”
BackgroundSelf-citationCommunity energy storage: A smart choice for the smart grid?
Barbour, E., Parra, D., Awwad, Z., & González, M. C. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.056 · Cited by 239
“To date, many studies have examined the techno-economic impacts of PV-coupled batteries in individual dwellings, examining the required conditions for economic profitability in terms of capital expenditure as well as retail tariffs and export prices [10, 11].”
Self-citationTang, Y., Zhang, Q., Li, Y., Wang, G., & Li, Y. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2018.03.043 · Cited by 236
Mulleriyawage, U. G. K., & Shen, W. X. (2020) · Renewable Energy · doi:10.1016/j.renene.2020.07.022 · Cited by 204
Hahnel, U. J. J., Herberz, M., Pena-Bello, A., Parra, D., & Brosch, T. (2020) · Energy Policy · doi:10.1016/j.enpol.2019.111098 · Cited by 203
Self-citationEconomic assessment of photovoltaic battery systems based on household load profiles
Schopfer, S., Tiefenbeck, V., & Staake, T. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.03.185 · Cited by 194
“Regarding political boundary conditions, a number of articles assess how electricity retail tariffs [16,32,24,17], interest rates [33,34], and subsidy schemes [27] affect the economic viability of grid-connected residential PVB systems, and others evaluate the role of feed-in tariffs in near- and post-grid parity mark…”
BackgroundOptimum community energy storage for renewable energy and demand load management
Parra, D., Norman, S. A., Walker, G. S., & Gillott, M. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.048 · Cited by 184
“This study does not include a sensitivity analysis but the impact of various input parameters on the techno-economic benefits of residential batteries was already analysed for single homes [42, 43] and communities [28] respectively.”
Self-citationSegundo Sevilla, F. R., Parra, D., Wyrsch, N., Patel, M. K., Kienzle, F., & Korba, P. (2018) · Journal of Energy Storage · doi:10.1016/j.est.2018.02.001 · Cited by 95
“Likewise, optimal battery capacities have also been determined for particular locations such as single homes [9] and communities [11].”
BackgroundResultInfluentialSelf-citationPena-Bello, A., Barbour, E., Gonzalez, M. C., Patel, M. K., & Parra, D. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.06.003 · Cited by 79
Self-citationThe nature of combining energy storage applications for residential battery technology
Parra, D., & Patel, M. K. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.218 · Cited by 63
Self-citation
Metadata
- Authors
- Parra, D., & Patel, M. K.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 164
- Pages
- 175-187
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2208045813
- Cited by
- 122
- References
- 1
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.