Parametric study on the regeneration heat requirement of an amine-based solid adsorbent process for post-combustion carbon capture

Open access
Zhang, Wenbin, Liu, Hao, Sun, Yuan, Cakstins, Janis, Sun, Chenggong, Snape, Colin E. · 2016 · Applied Energy

Abstract

The thermal energy required for regeneration of CO2-rich adsorbents or absorbents is usually regarded as the most important criterion to evaluate different materials and processes for application in commercial-scale CO2 capture systems. It is expected that the regeneration heat can be greatly reduced by replacing the mature aqueous monoethanolamine (MEA) technology with amine-based solid adsorbents capturing systems, due to the much lower heat capacity of solid adsorbents comparing to aqueous MEA and the avoidance of evaporating a large amount of water in the regenerator. Comparing to the MEA technology, the regeneration heat for solid adsorbent based systems has not received adequate attention especially on the impacts of process related parameters. Further, the methodologies used in previous investigations to calculate the regeneration heat may have deficiencies in defining the working capacities, adopting proper heat recovery strategies and/or evaluating the effect of moisture co-adsorption. In this study, an energy equation to calculate the regeneration heat has been revised and proposed to systematically evaluate the most important parameters affecting the regeneration heat, including the physical properties of the adsorbents and process related variables including the heat of adsorption, specific heat capacity, working capacity, moisture adsorption of the polyethyleneimine (PEI)/silica adsorbent, the swing temperature difference and the degree of heat recovery. Based on the parametric analysis, the calculated regeneration heat for the PEI/silica adsorbent based system is found to be around 2.46 GJ/tCO2, which is much lower than the value of 3.9 GJ/tCO2 for a typical aqueous MEA system and is also lower than 3.3 GJ/tCO2 for an advanced MEA system. Sensitivity analysis of all the parameters has also been conducted and the results have shown that working capacity, moisture adsorption and heat recovery ratios are the most influential factors. With more proficiency and development in the energy efficient process designs, the advantages of a solid adsorbent based capturing system over typical MEA systems will be justified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2016.01.049

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Zhang, W., Liu, H., Sun, Y., Cakstins, J., Sun, C., & Snape, C. E.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2016-04
Volume
168
Pages
394-405
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2272579245
Cited by
192
References
1
FWCI
17.41
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Parametric study on the regeneration heat requirement of an amine-based solid adsorbent process for post-combustion carbon capture. https://app.cochat.ai/papers/10.1016/j.apenergy.2016.01.049
The paper
Zhang, W., Liu, H., Sun, Y., Cakstins, J., Sun, C., & Snape, C. E. (2016). Parametric study on the regeneration heat requirement of an amine-based solid adsorbent process for post-combustion carbon capture. Applied Energy. https://doi.org/10.1016/j.apenergy.2016.01.049

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.