Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Deep learning-based fault diagnosis of variable refrigerant flow air-conditioning system for building energy saving

Guo, Yabin, Tan, Zehan, Chen, Huanxin, Li, Guannan, Wang, Jiangyu, Huang, Ronggeng, Liu, Jiangyan, Ahmad, Tanveer · 2018 · Applied Energy

Abstract

The fault diagnosis of air-conditioning systems is of great significance to the energy saving of buildings. This study proposes a novel fault diagnosis approach for building energy saving based on the deep learning method which is deep belief network, and its application potential in the air conditioning fault diagnosis field is investigated. Then, a parameter optimization selection strategy is developed for model optimization. Four kinds of faults of the variable flow refrigerant system under heating mode are used to evaluate the performance of the models. The fault diagnosis results show that the deep belief network model with initial parameters can be used to diagnose the faults of the variable flow refrigerant system. Through the parameter optimization selection strategy, the fault diagnosis correct rate of the optimized model is 97.7%, which is improved by 5.05% compared with the model with initial parameters. The number of hidden layers of the deep belief network model is selected to be 2 layers. This result indicates that the fault diagnosis for variable flow refrigerant systems may not require a very deep model. Additionally, the performance of the optimized deep belief network model is compared with that of the traditional back propagation neural network, and the former is better. This finding also shows that the unsupervised restricted Boltzmann machine layer for data feature reconstruction can improve the fault diagnosis performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2018.05.075

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 170

Metadata

Authors
Guo, Y., Tan, Z., Chen, H., Li, G., Wang, J., Huang, R., Liu, J., & Ahmad, T.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2018-09
Volume
225
Pages
732-745
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2804601703
Cited by
170
References
4
FWCI
11.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep learning-based fault diagnosis of variable refrigerant flow air-conditioning system for building energy saving. https://app.cochat.ai/papers/10.1016/j.apenergy.2018.05.075
The paper
Guo, Y., Tan, Z., Chen, H., Li, G., Wang, J., Huang, R., Liu, J., & Ahmad, T. (2018). Deep learning-based fault diagnosis of variable refrigerant flow air-conditioning system for building energy saving. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.05.075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.