The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Compact liquid cooling strategy with phase change materials for Li-ion batteries optimized using response surface methodology
Abstract
The hybrid system that integrates active cooling into phase change materials (PCMs)/expanded graphite (EG) shows great prospects for power battery thermal management. But because of the heavy weight, the system need to be optimized with a balance of the cooling capacity contributed by the active and passive cooling. This study develops an optimization method based on the response surface methodology (RSM) and a numerical heat transfer model to minimize the weight and volume of such a battery thermal management system. With the PCM thermo-physical property models incorporated, the method can optimize the PCM composition along with the active cooling structure – taking the contributions of both the active and passive cooling into account. We minimize the PCM mass of the system with this method, and analyze the effects of the PCM composition, the battery module layouts and the active cooling configuration on the thermal management performance. Then we present an optimal design for this hybrid thermal management system, which helps save the PCM mass by up to 94.1% and the volume by up to 55.6%. The thermal management performance of the design is verified with an experiment. The results show the maximum battery temperature in a 20-battery module during the 1.5C discharge is limited to 37.0 °C while the maximum temperature difference is limited to be smaller than 3 °C. Compared with the conventional liquid cooling system, the hybrid system is not only highly efficient, but lightweight, with simple structure and flexible to the batteries with arbitrary shapes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Samimi, F., Babapoor, A., Azizi, M., & Karimi, G. (2016) · Energy · doi:10.1016/j.energy.2015.12.064 · Cited by 372
Cited by
Luo, J., Zou, D., Wang, Y., Wang, S., & Huang, L. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132741 · Cited by 813
A review on recent progress, challenges and perspective of battery thermal management system
Lin, J., Liu, X., Li, S., Zhang, C., & Yang, S. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.120834 · Cited by 588
Kong, D., Peng, R., Ping, P., Du, J., Chen, G., & Wen, J. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.112280 · Cited by 423
Chen, J., Kang, S., E, J., Huang, Z., Wei, K., Zhang, B., Zhu, H., Deng, Y., Zhang, F., & Liao, G. (2019) · Journal of Power Sources · doi:10.1016/j.jpowsour.2019.227228 · Cited by 392
Cheng, P., Chen, X., Gao, H., Zhang, X., Tang, Z., Li, A., & Wang, G. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.105948 · Cited by 348
Metadata
- Authors
- Ling, Z., Cao, J., Zhang, W., Zhang, Z., Fang, X., & Gao, X.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 228
- Pages
- 777-788
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2815151016
- Cited by
- 205
- References
- 1
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compact liquid cooling strategy with phase change materials for Li-ion batteries optimized using response surface methodology. https://app.cochat.ai/papers/10.1016/j.apenergy.2018.06.143
- The paper
- Ling, Z., Cao, J., Zhang, W., Zhang, Z., Fang, X., & Gao, X. (2018). Compact liquid cooling strategy with phase change materials for Li-ion batteries optimized using response surface methodology. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.06.143
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.