A centralized-based method to determine the local voltage control strategies of distributed generator operation in active distribution networks
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The increasing penetration of distributed generators (DGs) exacerbates the risk of voltage violations in active distribution networks (ADNs). The var capacity provided by DG inverters is a potential solution for voltage regulation. The conventional centralized control strategies limited by computation and communication burdens are difficult to meet the requirement of rapid voltage control. However, the local control strategies based on real-time measurements have a fast response to the frequent fluctuations of DG outputs. The performance of these local controllers depends on the tuning of the control parameters. This paper proposes a centralized-based method to determine the local voltage control strategies for DGs. A centralized parameter tuning model of control curves is built, in which Q-V and Pcurt-V curves of DG inverters are mathematically formulated based on piecewise linearization. The original mixed-integer nonlinear programming (MINLP) model is converted into an effectively solved mixed-integer second-order cone programming (MISOCP) model using convex relaxation. The potential benefits of DG inverters are explored to regulate both reactive and curtailed active power, based on local voltage measurements. Case studies on a modified PG&E 69-node distribution system are carried out to verify the effectiveness of the proposed method. Results show that power losses of ADNs are significantly reduced and voltage profiles are also improved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
Demirok, E., González, P. C., Frederiksen, K. H. B., Sera, D., Rodriguez, P., & Teodorescu, R. (2011) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2011.2174821 · Cited by 530
Cited by
Sun, X., & Qiu, J. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2021.3052998 · Cited by 289
A Multi-Agent Deep Reinforcement Learning Based Voltage Regulation Using Coordinated PV Inverters
Cao, D., Hu, W., Zhao, J., Huang, Q., Chen, Z., & Blaabjerg, F. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3000652 · Cited by 275
Self-citationOptimal local volt/var control for photovoltaic inverters in active distribution networks
Sun, X., Qiu, J., & Zhao, J. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3080039 · Cited by 111
Self-citationSun, X., Qiu, J., Yi, Y., & Tao, Y. (2022) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2021.3118404 · Cited by 87
Data-driven combined central and distributed volt/var control in active distribution networks
Sun, X., Qiu, J., Tao, Y., & Zhao, J. (2023) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3213587 · Cited by 42
“In [18], local active/reactive power-volage (Q(V) and Pcurt(V)) curves are first analytically modeled by piecewise linear functions,”
BackgroundMethodSelf-citation
Metadata
- Authors
- Ji, H., Wang, C., Li, P., Zhao, J., Song, G., Ding, F., & Wu, J.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 228
- Pages
- 2024-2036
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2883647357
- Cited by
- 106
- References
- 3
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.