The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Recent developments in solid desiccant coated heat exchangers – A review
Abstract
Abstract Rapid urbanization and higher thermal comfort requirements have sharply increased buildings’ energy demands. In tropical countries, for achieving energy efficient air-conditioning, desiccant dehumidifiers, which decouple sensible and latent load, are essential. While fixed-bed and rotary wheel desiccant dehumidifiers suffer from reduced adsorption capacity and lowered heat transfer efficiencies, desiccant coated heat exchanger (DCHE) system is a promising technology that can improve the energy efficiency of the standard vapor-compression air conditioners. Moreover, DCHEs also have prospective benefits in heat pump, adsorption chiller, and atmospheric water harvesting applications. In this paper, the advantages of DCHEs over other dehumidifiers are established, and a comprehensive review of various desiccant materials and binders used in DCHEs is carried out. The possibilities of using advanced materials to achieve superior energy efficiencies are also underlined. Different methods of coating the desiccant on heat exchangers are described, and quantitative parameters required to analyze the performance of the system are presented. Operating parameters affecting the dehumidification and thermal performance are identified, and the effect of their variation on the dynamic behavior of DCHEs is elaborately studied. The significance of using mathematical models as design tools is recognized, and the underlying assumptions, applicability, and limitations of the models for simulating the complex heat and mass transfer phenomenon are highlighted. The possibility of integrating an additional heat transfer equipment such as sensible heat exchangers, heat recovery devices, solar evacuated tube collectors, cooling towers, and evaporative coolers with DCHE is also presented. Finally, the potential system-level applications of DCHEs as heat pumps, adsorption chillers, water harvesters, and standalone air-conditioners are assessed. This review paper provides an update on recent developments in desiccant dehumidification and is intended to be a “one-stop” archive of known practical solutions that DCHEs can offer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649
Technical development of rotary desiccant dehumidification and air conditioning: A review
La, D., Dai, Y. J., Li, Y., Wang, R. Z., & Ge, T. S. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2009.07.016 · Cited by 357
Desiccant cooling systems: a review
Sahlot, M., & Riffat, S. B. (2016) · International Journal of Low-Carbon Technologies · doi:10.1093/ijlct/ctv032 · Cited by 129
Cited by
Water and Metal–Organic Frameworks: From Interaction toward Utilization
Liu, X., Wang, X., & Kapteijn, F. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00746 · Cited by 614
Adsorption-based atmospheric water harvesting
Ejeian, M., & Wang, R. Z. (2021) · Joule · doi:10.1016/j.joule.2021.04.005 · Cited by 416
Metadata
- Authors
- Vivekh, P., Kumja, M., Bui, D. T., & Chua, K. J.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 229
- Pages
- 778-803
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2887763439
- Cited by
- 219
- References
- 3
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent developments in solid desiccant coated heat exchangers – A review. https://app.cochat.ai/papers/10.1016/j.apenergy.2018.08.041
- The paper
- Vivekh, P., Kumja, M., Bui, D. T., & Chua, K. J. (2018). Recent developments in solid desiccant coated heat exchangers – A review. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.08.041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.