CoChat

Numerical investigation of the thermal performance enhancement of latent heat thermal energy storage using longitudinal rectangular fins and flat micro-heat pipe arrays

Diao, Y.H., Liang, L., Zhao, Y.H., Wang, Z.Y., Bai, F.W. · 2019 · Applied Energy
Cited by 90

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The performance of a new type of latent heat thermal energy storage (LHTS) device based on flat micro-heat pipe arrays (FMHPAs) with longitudinal rectangular fins is numerically studied by enthalpy–porosity technique based on finite volume method (FVM) in this research. The numerical model is verified correct. The temperature distribution and phase transition process in different directions of the interior of a thermal storage tank and the effects of fin height, spacing, and thickness on charging power and thermal storage capacity are also analyzed numerically. Results show that phase interface is presented in U type in the horizontal direction. In the vertical direction, the phase change material (PCM) among fins melts from up to down when the fin spacing is larger than 6 mm, and the opposite occurs when the fin spacing is less than 6 mm. The thermal storage capacity of the LHTS device is reduced drastically when the fin spacing is less than 4.14 mm. For fin height, the structure of multiple rows of FMHPAs with dwarf fins is recommended because it exhibits large power and exerts a small negative effect on thermal storage capacity. Fin thickness has a minimal effect on charging power and thermal storage capacity. The study results provide optimization design guidance for LHTS devices based on FMHPAs under various application backgrounds, such as solving the contradiction between energy supply and demand in solar thermal systems and the peak load shifting of electricity in heat pump systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2018.10.024

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Diao, Y. H., Liang, L., Zhao, Y. H., Wang, Z. Y., & Bai, F. W.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2019-01
Volume
233-234
Pages
894-905
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2898992016
Cited by
90
References
4
FWCI
7.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Numerical investigation of the thermal performance enhancement of latent heat thermal energy storage using longitudinal rectangular fins and flat micro-heat pipe arrays. https://app.cochat.ai/papers/10.1016/j.apenergy.2018.10.024
The paper
Diao, Y. H., Liang, L., Zhao, Y. H., Wang, Z. Y., & Bai, F. W. (2019). Numerical investigation of the thermal performance enhancement of latent heat thermal energy storage using longitudinal rectangular fins and flat micro-heat pipe arrays. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.10.024

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.