Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 217

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Effects of moderate thermal environments on cognitive performance: A multidisciplinary review

Open access
Zhang, Fan, de Dear, Richard, Hancock, Peter·2019·Applied Energy

Abstract

Abstract The effect of the thermal environment on performance and productivity has been a focus of interest among indoor environmental researchers for nearly a century, but most of that work has been conducted in relative isolation from the cognate disciplines of human performance evaluation. The present review examines thermal environmental effects on cognitive performance research conducted across multiple disciplines. After differentiating performance from productivity, we compare the two dominant conceptual models linking thermal stress to performance; (1) the inverted-U concept and (2) the extended-U relationship. The inverted-U specifies a single optimum temperature (or its corresponding subjective thermal sensation) at which performance is maximised. In contrast, the extended-U model posits a broad central plateau across which there is no discernible thermal effect on cognitive performance. This performance plateau is bounded by regions of progressive performance decrements in more extreme thermal conditions. The contradictions between these opposing conceptual models might derive from various confounding factors at play in their underlying research bases. These include, inter alia, environment-related, task-related, and performer-related factors, as well as their associated two-way and three-way interaction effects. Methodological discrepancies that might also contribute to the divergence of these conceptual models are evaluated, along with the proposed causal mechanisms underlying the two models. The weight of research evidence reviewed in this paper suggests that the extended-U hypothesis fits the relationship between moderate thermal environments and cognitive performance. In contrast to the inverted-U relationship, implemention of the extended-U in indoor climate control implies substantial reductions in building energy demand, since it permits the heating and cooling setpoint deadband to expand across the full width of the thermal comfort zone, or even slightly further during emergencies such as peak demand events on the electricity grid. Use of personal comfort systems can further extend the thermostat setpoint range beyond the comfort zone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2018.12.005

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 217

Metadata

Authors
Zhang, F., de Dear, R., & Hancock, P.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2019-02
Volume
236
Pages
760-777
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2904680339
Cited by
217
References
32
FWCI
12.13
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of moderate thermal environments on cognitive performance: A multidisciplinary review. https://app.cochat.ai/papers/10.1016/j.apenergy.2018.12.005
The paper
Zhang, F., de Dear, R., & Hancock, P. (2019). Effects of moderate thermal environments on cognitive performance: A multidisciplinary review. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.12.005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.