Economic model predictive control of combined thermal and electric residential building energy systems
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This article investigates the potential of economic model predictive control of complex residential energy systems with electric coupling to the public grid. The examined system includes a battery energy storage system, photovoltaic power generation, an air-to-water heat pump, thermal energy storage and a building model. The said power generation provides energy for electric loads as well as domestic hot water and space heating. Model predictive control algorithms manage the energy system by nonlinear global optimization. Within this optimization, a time-varying state space model, which is derived from the energy system simulation model, reflects the system dynamics. Owing to the resulting high complexity, two algorithms for distributed model predictive control are developed. In addition, the developed approaches are compared to a common reference control concept as well as centralized model predictive control. For the comparison of annual operational costs, current German energy prices and subsidies are implemented into the economic calculation. Results show an improved performance of the developed approaches with 11.6% cost reduction in comparison to the reference. This is achieved through an increase of the heat pump seasonal performance factor by 3.4%, reduced curtailment of electrical photovoltaic energy to 21.5% of the reference value and prevention of auxiliary heater operation. Furthermore, increased photovoltaic self-consumption by the heat pump results in a slight reduction of battery storage operation. In conjunction with monetary and energetic advantages, model predictive control increases the comfort in regards to the violation of minimum limits for the comfort criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on simulation-based optimization methods applied to building performance analysis
Nguyen, A.-T., Reiter, S., & Rigo, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.08.061 · Cited by 1,379
Cited by
All you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020
Joe, J., & Karava, P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.03.209 · Cited by 232
Sun, L., & You, F. (2021) · Engineering · doi:10.1016/j.eng.2021.04.020 · Cited by 202
“EMPC has already been studied in the throttling loss minimization of a boiler–turbine unit [17] and the comfort maximization of a building cogeneration system [18].”
BackgroundHu, Z., Gao, Y., Sun, L., Mae, M., & Imaizumi, T. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123652 · Cited by 52
Banfield, B., Robinson, D. A., & Agalgaonkar, A. P. (2020) · IET Smart Grid · doi:10.1049/iet-stg.2020.0090 · Cited by 17
Metadata
- Authors
- Kuboth, S., Heberle, F., König-Haagen, A., & Brüggemann, D.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 240
- Pages
- 372-385
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2914867085
- Cited by
- 125
- References
- 1
- FWCI
- 12.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Economic model predictive control of combined thermal and electric residential building energy systems. https://app.cochat.ai/papers/10.1016/j.apenergy.2019.01.097
- The paper
- Kuboth, S., Heberle, F., König-Haagen, A., & Brüggemann, D. (2019). Economic model predictive control of combined thermal and electric residential building energy systems. Applied Energy. https://doi.org/10.1016/j.apenergy.2019.01.097
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.