Optimal scheduling strategy of district integrated heat and power system with wind power and multiple energy stations considering thermal inertia of buildings under different heating regulation modes
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Utilizing multiple energy supply solutions and the thermal inertia of buildings are considered as an efficient method for improving energy conservation and the operational flexibility of Combined Heat and Power (CHP) for wind power integration in a district integrated heat and power system (DIHPS). However, to truly take advantage of these, many factors such as the energy price, the variable efficiency of devices, and especially the different heating regulation modes (the quantity regulation and the quality regulation mode) are imperative to be considered for variable situations of the practical project. Therefore, in this paper, an integrated hydraulic-thermal model of the district heating network (DHN) under the quantity regulation mode is introduced, and a novel thermal energy flow model with transmission time delay under the quality regulation mode is firstly proposed to simulate the dynamic thermal energy distribution of the DHN with multiple heat sources. Then, in terms of different heating regulation modes, the different thermal capacity of buildings to increase the flexibility of the DIHPS is studied. Moreover, an optimal scheduling method considering different energy stations and the thermal inertia of buildings under different heating regulation modes is proposed to guide the operation of the DIHPS in variable actual engineering applications for the sake of operational economics and wind power utilization. Finally, numerical cases have been compared based on a modified testing system. The results demonstrate that under the quantity regulation mode the coordination of energy stations effectively reduces the daily operation cost by 17.4%. The thermal inertia of buildings give a saving rate of 6.4% and he penalty cost of wind power is reduced by 36.3% further. Moreover, the total thermal capacity of buildings to reduce the operation cost and the wind power curtailment is less under the quality regulation mode. It results that the daily operation cost increases by 4.1%. In addition, towards the DIHPS with multiple energy stations in our case, the thermal inertia of pipes cloud not reduce the daily operation cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An open source platform for collaborating on smart grid research
Dugan, R. C., & McDermott, T. E. (2011) · 2011 IEEE Power and Energy Society General Meeting · doi:10.1109/pes.2011.6039829 · Cited by 533
Cited by
Alabi, T. M., Aghimien, E. I., Agbajor, F. D., Yang, Z., Lu, L., Adeoye, A. R., & Gopaluni, B. (2022) · Renewable Energy · doi:10.1016/j.renene.2022.05.123 · Cited by 266
Metadata
- Authors
- Wang, D., Zhi, Y.-Q., Jia, H.-J., Hou, K., Zhang, S.-X., Du, W., Wang, X.-D., & Fan, M.-H.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 240
- Pages
- 341-358
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2911782189
- Cited by
- 168
- References
- 1
- FWCI
- 8.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.