Dynamic modeling and small signal stability analysis of distributed photovoltaic grid-connected system with large scale of panel level DC optimizers
The DOI matches its Crossref record.
Abstract
The distributed maximum power point tracking (DMPPT) technologies, based on a DC optimizer (DCO) for every single photovoltaic (PV) panel, are increasingly proposed to mitigate the waste of solar energy due to the mismatch problems of PV arrays. However, the stability problem of DMPPT based distributed PV grid-connected systems that involve a large amount of DCOs remains to be further studied. Therefore, modeling, deservedly, is the basis for stability analysis. Usually the model of the PV power plant consists of hundreds or even thousands of DCOs, which results in a heavy computation burden during the simulation. To solve the modeling problem, this paper proposes a matrix variables based modeling method for the distributed PV grid-connected system. The core idea of the modeling method is to convert the complex model that contains plenty of PV-DCO generation units to an average model consisting of only two typical submodules, by constructing the block matrix formed variables. In this way, the model has the advantages of good scalability and high simulation efficiency, and can be realized by the vector simulation feature of Matlab/Simulink. Besides, it is easy to obtain the linearization results directly by using the Linearization Toolbox in Simulink, which avoids the complexity of writing programs for linearization calculation when studying the stability of large-scale systems. Based on the average model and corresponding linearization results, the key impacts on the small signal stability of the system are determined via the eigenvalue analysis method and root locus method. It is shown that the total active power output by PV array, the controller parameters of the grid-connected inverter, and the strength of the AC system are critical factors affecting the small signal stability of distributed PV grid-connected system. Different simulation results verify the effectiveness of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, Z., Feng, G., Zhen, D., Gu, F., & Ball, A. (2021) · Energy Reports · doi:10.1016/j.egyr.2021.08.113 · Cited by 441
Shi, Z., Yao, W., Li, Z., Zeng, L., Zhao, Y., Zhang, R., Tang, Y., & Wen, J. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115733 · Cited by 327
Self-citationYang, B., Zhu, T., Wang, J., Shu, H., Yu, T., Zhang, X., Yao, W., & Sun, L. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.121983 · Cited by 264
Self-citationShi, Z., Yao, W., Zeng, L., Wen, J., Fang, J., Ai, X., & Wen, J. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114586 · Cited by 239
Self-citationYang, B., Liu, B., Zhou, H., Wang, J., Yao, W., Wu, S., Shu, H., & Ren, Y. (2022) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-022-00239-w · Cited by 197
Self-citation
Metadata
- Authors
- Wang, Q., Yao, W., Fang, J., Ai, X., Wen, J., Yang, X., Xie, H., & Huang, X.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 259
- Pages
- 114132
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2990980457
- Cited by
- 101
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic modeling and small signal stability analysis of distributed photovoltaic grid-connected system with large scale of panel level DC optimizers. https://app.cochat.ai/papers/10.1016/j.apenergy.2019.114132
- The paper
- Wang, Q., Yao, W., Fang, J., Ai, X., Wen, J., Yang, X., Xie, H., & Huang, X. (2020). Dynamic modeling and small signal stability analysis of distributed photovoltaic grid-connected system with large scale of panel level DC optimizers. Applied Energy. https://doi.org/10.1016/j.apenergy.2019.114132
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.