CoChat

Dynamic modeling and small signal stability analysis of distributed photovoltaic grid-connected system with large scale of panel level DC optimizers

Wang, Qin, Yao, Wei, Fang, Jiakun, Ai, Xiaomeng, Wen, Jinyu, Yang, Xiaobo, Xie, Hailian, Huang, Xing · 2020 · Applied Energy
Cited by 101

The DOI matches its Crossref record.

Abstract

The distributed maximum power point tracking (DMPPT) technologies, based on a DC optimizer (DCO) for every single photovoltaic (PV) panel, are increasingly proposed to mitigate the waste of solar energy due to the mismatch problems of PV arrays. However, the stability problem of DMPPT based distributed PV grid-connected systems that involve a large amount of DCOs remains to be further studied. Therefore, modeling, deservedly, is the basis for stability analysis. Usually the model of the PV power plant consists of hundreds or even thousands of DCOs, which results in a heavy computation burden during the simulation. To solve the modeling problem, this paper proposes a matrix variables based modeling method for the distributed PV grid-connected system. The core idea of the modeling method is to convert the complex model that contains plenty of PV-DCO generation units to an average model consisting of only two typical submodules, by constructing the block matrix formed variables. In this way, the model has the advantages of good scalability and high simulation efficiency, and can be realized by the vector simulation feature of Matlab/Simulink. Besides, it is easy to obtain the linearization results directly by using the Linearization Toolbox in Simulink, which avoids the complexity of writing programs for linearization calculation when studying the stability of large-scale systems. Based on the average model and corresponding linearization results, the key impacts on the small signal stability of the system are determined via the eigenvalue analysis method and root locus method. It is shown that the total active power output by PV array, the controller parameters of the grid-connected inverter, and the strength of the AC system are critical factors affecting the small signal stability of distributed PV grid-connected system. Different simulation results verify the effectiveness of the proposed approach.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2019.114132

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 101

Metadata

Authors
Wang, Q., Yao, W., Fang, J., Ai, X., Wen, J., Yang, X., Xie, H., & Huang, X.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2020-02
Volume
259
Pages
114132
ISSN
0306-2619 (ISSN-L)
OpenAlex
W2990980457
Cited by
101
References
0
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic modeling and small signal stability analysis of distributed photovoltaic grid-connected system with large scale of panel level DC optimizers. https://app.cochat.ai/papers/10.1016/j.apenergy.2019.114132
The paper
Wang, Q., Yao, W., Fang, J., Ai, X., Wen, J., Yang, X., Xie, H., & Huang, X. (2020). Dynamic modeling and small signal stability analysis of distributed photovoltaic grid-connected system with large scale of panel level DC optimizers. Applied Energy. https://doi.org/10.1016/j.apenergy.2019.114132

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.