State-of-the-art of controllers and soft computing techniques for regulated load frequency management of single/multi-area traditional and renewable energy based power systems
The DOI matches its Crossref record; 204 of the 204 references it cites were found in a registry or an index.
Abstract
Abstract Load frequency management (LFM) has become more significant in modern power systems due to variation demand and generation profiles. Further, integration of renewable energy resources (RSs) into the power systems makes LFM job more challenging. To this end, the concept of secondary frequency control, or LFM, objective is introduced to single and multi-area power systems to manage the power mismatch of the particular power system. This helps regulate the system frequency for single/multi area systems and schedule tie-line power exchange for multi area systems. To control and reduce the system frequency deviation, load frequency controllers are introduced. However, to achieve optimal power management, intelligent soft computing techniques that take different controllers into account are utilized. This paper aims to provide a review of different controllers utilized in traditional as well as renewable energy-based power system for LFM such as; classical controllers, fractional order controllers, cascaded controllers, sliding mode controller (SMC), tilt-integral-derivative controllers, H-infinity controller and other recently developed controllers. Some popular and recently adopted soft-computing tools for power management such as; genetic algorithm, particle swarm optimization, firefly, cuckoo search techniques, fuzzy tuning tool, model predictive technique and other newer once have been explored. Finally, the paper concludes by highlighting some future scope in the field of LFM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–204 of 204
An Analysis of Two Area Load Frequency Control with Different Types of Feedback Controllers
Hore, D. (2014) · Cited by 9
Load frequency control system with smart meter and controllable loads
Khalil, A. F., & Rajab, Z. (2017) · International Renewable Energy Congress · doi:10.1109/irec.2017.7926033 · Cited by 8
Dutta, A., & Debbarma, S. (2018) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2018.8352345 · Cited by 7
Model Predictive Load Frequency Control of two-area Interconnected Time Delay Power System with TCSC
Deng, Y., & Liu, W. (2017) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/199/1/012064 · Cited by 7
Cited by
High-Level Penetration of Renewable Energy Sources Into Grid Utility: Challenges and Solutions
Alam, M. S., Al-Ismail, F. S., Salem, A., & Abido, M. A. (2020) · IEEE Access · doi:10.1109/access.2020.3031481 · Cited by 431
Cheng, Y., Azizipanah-Abarghooee, R., Azizi, S., Ding, L., & Terzija, V. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.115798 · Cited by 194
Metadata
- Authors
- Latif, A., Hussain, S. M. S., Das, D. C., & Ustun, T. S.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 266
- Pages
- 114858
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3011490572
- Cited by
- 183
- References
- 204
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.