The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
Hybrid design of PID controller for four DoF lower limb exoskeleton
Open accessAbstract
In this paper, a method of tuning a proportional-integral-derivative controller for a four degree-of-freedom lower limb exoskeleton using hybrid of genetic algorithm and particle swarm optimization is presented. Transfer function of each link of the lower limb exoskeleton acquired from a pendulum model, was used in a closed-loop proportional-integral-derivative control system, while each link was assumed as one degree-of-freedom linkage. In the control system, the hybrid algorithm was applied to acquire the parameters of the controller for each joint for minimizing the error. The algorithm started with genetic algorithm and continued via particle swarm optimization. Furthermore, a 3-dimensional model of the lower limb exoskeleton was simulated to validate the proposed controller. The trajectory of the control system with optimized proportional-integral-derivative controller via hybrid precisely follows the input signal of the desired. The result of the hybrid optimized controller was compared with genetic algorithm and particle swarm optimization based on statistics. The average error of the proposed algorithm showed the optimized results in comparison with genetic algorithm and particle swarm optimization. Furthermore, the advantages of the hybrid algorithm have been indicated by numerical analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The linear control algorithms, which are developed using conventional PID [11-14] or feedback linearization techniques [15,16], are simple and easy to implement in engineering. However, they only perform well under certain operating conditions, and fail to achieve satisfactory performance in the presence of aforementioned uncertainties, including parameter permutations, nonlinearities and disturb”
From Compensation Function Observer-Based Backstepping Sliding-Mode Control of Uncertain Electro-Hydraulic Servo System (2024) · cites this paper as [14]
Citations
Cites
PID Controllers: Theory, Design, and Tuning
Åström, K. J., & Hägglund, T. J. (1995) · Lund University Publications (Lund University) · Cited by 4,741
(1978) · Chemical & Engineering News Archive · doi:10.1021/cen-v056n033.p045 · Cited by 1,834
(2003) · Chemical Industries · doi:10.1201/9780203911501.ch5 · Cited by 953
Mohanty, B., Panda, S., & Hota, P. K. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.06.029 · Cited by 438
Neural Network Control of a Rehabilitation Robot by State and Output Feedback
He, W., Ge, S. S., Li, Y., Chew, E., & Ng, Y. S. (2015) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-014-0150-6 · Cited by 258
Adaptive Impedance Control of a Robotic Orthosis for Gait Rehabilitation
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2013) · IEEE Transactions on Cybernetics · doi:10.1109/tsmcb.2012.2222374 · Cited by 223
Shunmugapriya, P., & Kanmani, S. (2017) · Swarm and Evolutionary Computation · doi:10.1016/j.swevo.2017.04.002 · Cited by 216
ros_control: A generic and simple control framework for ROS
Chitta, S., Marder-Eppstein, E., Meeussen, W., Pradeep, V., Rodríguez Tsouroukdissian, A., Bohren, J., Coleman, D., Magyar, B., Raiola, G., Lüdtke, M., et al. (2017) · The Journal of Open Source Software · doi:10.21105/joss.00456 · Cited by 209
The design and control of a 3DOF lower limb rehabilitation robot
Wu, J., Gao, J., Song, R., Li, R., Li, Y., & Jiang, L. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.11.010 · Cited by 144
Design of an active one-degree-of-freedom lower-limb exoskeleton with inertia compensation
Aguirre-Ollinger, G., Colgate, J. E., Peshkin, M. A., & Goswami, A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910385730 · Cited by 140
Research works printed but not linked: 1
- Baluch, 2012, 6, 812
Cited by
Feng, H., Song, Q., Ma, S., Ma, W., Yin, C., Cao, D., & Yu, H. (2022) · ISA Transactions · doi:10.1016/j.isatra.2021.12.044 · Cited by 230
Optimal fuzzy logic-based control strategy for lower limb rehabilitation exoskeleton
Sharma, R., Gaur, P., Bhatt, S., & Joshi, D. (2021) · Applied Soft Computing · doi:10.1016/j.asoc.2021.107226 · Cited by 70
Zhao, J., Yang, T., Sun, X., Dong, J., Wang, Z., & Yang, C. (2021) · Mechatronics · doi:10.1016/j.mechatronics.2021.102554 · Cited by 52
Amiri, M. S., Ramli, R., Ibrahim, M. F., Wahab, D. A., & Aliman, N. (2020) · Mathematics · doi:10.3390/math8112040 · Cited by 50
“The summation of the physical effect of each lower link such as mass and inertia is considered to be M i [24].”
BackgroundSelf-citationLiu, J., Fang, H., & Xu, J. (2021) · Machines · doi:10.3390/machines10010021 · Cited by 45
“For example, by employing the genetic algorithm and the particle swarm optimization (PSO) algorithm, an intelligent PID controller is proposed, which could effectively determine the PID gains for a 4-DOF lower extremity exoskeleton [36,37].”
MethodModel-free prescribed performance fixed-time control for wearable exoskeletons
Sun, J., Wang, J., Yang, P., & Guo, S. (2020) · Applied Mathematical Modelling · doi:10.1016/j.apm.2020.09.010 · Cited by 45
Foroutannia, A., Akbarzadeh-T, M.-R., Akbarzadeh, A., & Tahamipour-Z., S. M. (2023) · Mechatronics · doi:10.1016/j.mechatronics.2023.102952 · Cited by 44
Narayan, J., & Dwivedy, S. K. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/5573041 · Cited by 43
“The researchers, in the literature, have regarded the predefined gait tracking control as the basis of every control scheme for exoskeleton systems, where the joint movements of the lower limb could be estimated using gait analysis experiments [15, 16, 17].”
BackgroundRetractedInitialized Model Reference Adaptive Control for Lower Limb Exoskeleton
Amiri, M. S., Ramli, R., & Ibrahim, M. F. (2019) · IEEE Access · doi:10.1109/access.2019.2954110 · Cited by 43
“The LLE consists of two DoF in each leg [29].”
Self-citationOptimal parameter estimation for a DC motor using genetic algorithm
Amiri, M. S., Ibrahim, M. F., & Ramli, R. (2020) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v11.i2.pp1047-1054 · Cited by 43
“where, the initial values of the GA are set as follows, x rand x ε, x ε (14) where, ε is a positive random value between zero and one [25].”
BackgroundSelf-citationZhang, G., Wang, J., Yang, P., & Guo, S. (2021) · Applied Mathematical Modelling · doi:10.1016/j.apm.2021.03.049 · Cited by 37
Human-exoskeleton coupling dynamics in the swing of lower limb
Yan, Y., Chen, Z., Huang, C., Chen, L., & Guo, Q. (2021) · Applied Mathematical Modelling · doi:10.1016/j.apm.2021.12.007 · Cited by 34
Offline ANN-PID Controller Tuning on a Multi-Joints Lower Limb Exoskeleton for Gait Rehabilitation
Al-Waeli, K. H., Ramli, R., Haris, S. M., Zulkoffli, Z., & Amiri, M. S. (2021) · IEEE Access · doi:10.1109/access.2021.3101576 · Cited by 32
Self-citationAlawad, N. A., Humaidi, A. J., & Al-Araji, A. S. (2023) · Anais da Academia Brasileira de Ciências · doi:10.1590/0001-3765202320220680 · Cited by 36
Amiri, M. S., & Ramli, R. (2021) · Sensors · doi:10.3390/s21093171 · Cited by 28
“…where j stands for the number of particles in the first population and rand is the function used to generate a random value between x min and x max , which are the lower and higher bounds, given as follows [42]: x min = x ga − r (28) where r ∈ (cid:60) 1 × 4 is a random vector between zero and one.”
MethodSelf-citationAmiri, M. S., Ramli, R., & Ibrahim, M. F. (2020) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2020.103425 · Cited by 28
Self-citationSwarm Intelligence Approach for Angle Stability Improvement of PSS and SVC-Based SMIB
Kamari, N. A. M., Musirin, I., & Ibrahim, A. A. (2020) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-020-00386-w · Cited by 26
Simulation and Control of a Six Degree of Freedom Lower Limb Exoskeleton
Amiri, M. S., Ramli, R., Tarmizi, M. A. A., Ibrahim, M. F., & Narooei, K. D. (2020) · Jurnal Kejuruteraan · doi:10.17576/jkukm-2020-32(2)-03 · Cited by 23
Self-citationMechatronic Exoskeletons for Lower-Limb Rehabilitation: An Innovative Review
Huamanchahua, D., Taza-Aquino, Y., Bados, J. S. F., Villanueva, J. M. A., Vargas‐Martínez, A., & Ramírez-Mendoza, R. A. (2021) · IEEE International IOT, Electronics and Mechatronics Conference (IEMTRONICS) · doi:10.1109/iemtronics52119.2021.9422513 · Cited by 21
“Luna, L [15] PMI CRT 6 Aluminum S 2 Mohammad, S [16] PMI CR 4 NE NE 3 Wang, H [17] PMI CR 4 NE NE 6 Wang, Y [18] PMI CR 4 NE AL 1”
BackgroundModelling and analysis of coupling dynamics of swinging a lower limb exoskeleton
Yan, Y., Chen, Z., Huang, C., & Guo, Q. (2022) · Nonlinear Dynamics · doi:10.1007/s11071-022-07876-8 · Cited by 26
“To accurately track a given trajectory, many control algorithms, such as proportional-integralderivative (PID) [17,18], adaptive neural network [19], sliding-mode [20], etc., can be employed.”
Zhang, Y., Cao, G., Li, W., Chen, J., Li, L., & Diao, D. (2021) · Applied Sciences · doi:10.3390/app112110329 · Cited by 20
“Traditional control methods including proportional-integral-derivative (PID) control [14], computed torque method [15], adaptive control [16], and robust control [17] have difficulty in meeting the actual needs of patients using lower limb rehabilitation exoskeleton robots because their trajectory tracking abilities a…”
BackgroundWang, Y., Tian, Y., Guo, Y., & Wang, H. (2023) · Mathematics and Computers in Simulation · doi:10.1016/j.matcom.2023.08.020 · Cited by 19
Narayan, J., Abbas, M., & Dwivedy, S. K. (2024) · Transactions of the Institute of Measurement and Control · doi:10.1177/01423312241245764 · Cited by 18
“Unlike the previous studies in PA mode (Amiri et al., 2019; Narayan et al., 2023a; Yang et al., 2020; Zhang et al., 2018), this research focuses on active subject–exoskeleton compliance using the proposed cooperative control.”
Explicit model based fuzzy control method for lower limb exoskeleton robot
Lu, X., Chen, X., Bai, Y., & Liu, R. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.126601 · Cited by 17
PID Tuning Of Chopper Fed Speed Control Of DC Motor Based On Ant Colony Optimization Algorithm
Kouassi, B. A., Zhang, Y., Ouattara, S., & Kiki, M. J. M. (2019) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec47146.2019.cieec-2019179 · Cited by 15
“The Ant Colony Algorithm (ACO) is a metaheuristic behavior, which based on the swarm intelligence generated by the cooperation in a colony, particularly by pheromone communication between ants on a good path from the colony to a potential food source in an environment [14].”
BackgroundSun, J., Wang, J., Yang, P., Zhang, Y., & Chen, L. (2020) · International Journal of Control Automation and Systems · doi:10.1007/s12555-019-0975-7 · Cited by 16
A comprehensive review on lower limb exoskeleton: from origin to future expectations
Arunkumar, S., & Jayakumar, N. (2024) · International Journal on Interactive Design and Manufacturing (IJIDeM) · doi:10.1007/s12008-024-02076-7 · Cited by 17
“Hence, a robust and effective control strategy is the most important requirement of the LLE for achieving synchronous motion [125, 126].”
H∞ Control for Network T-S Fuzzy Systems under Time Varying Delay for Multi-area Power Systems
Aslam, M. S., & Dai, X. (2020) · International Journal of Control Automation and Systems · doi:10.1007/s12555-019-0844-4 · Cited by 14
Tracking control for lower limb rehabilitation robots based on polynomial nonlinear uncertain models
Li, Y., Ke, J., & Zeng, J. (2021) · International Journal of Robust and Nonlinear Control · doi:10.1002/rnc.5381 · Cited by 14
“Note that joint angles can be measured directly, the measurement output vector is defined as y = Cx, (7)”
BackgroundForoutannia, A., & Mohammadian, M. (2025) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2025.105232 · Cited by 16
Narayan, J., Kalita, B., & Dwivedy, S. K. (2023) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/09596518231191390 · Cited by 13
“In the past two decades, extensive research has been conducted on position/trajectory control methods for LLERs, including both non-robust 15,16 and robust approaches 17–22 for the LLERs to achieve a predefined gait trajectory.”
Human Gait Recognition Using Hip, Knee and Ankle Joint Ratios
Akhil, V. M., Ashmi, M., Rajendrakumar, P. K., & Sivanandan, K. S. (2019) · IRBM · doi:10.1016/j.irbm.2019.11.001 · Cited by 14
Research on Control Strategy of Lower Limb Exoskeleton Robots: A Review
Xu, X. F., Chen, C., Sun, Z., Xian, W., Ma, L., & Liu, Y. (2026) · Sensors · doi:10.3390/s26020355 · Cited by 12
“Amiri et al. [75] proposed a method using genetic algorithms and PSO to tune the PID controller of a 4-DOF lower limb exoskeleton.”
Phu, D. X., Van, M., & Choi, S. (2021) · Applied Sciences · doi:10.3390/app11052244 · Cited by 12
“However, because of large number of iterations, the proposed control proposed in [7] has large time delay in practice.”
BackgroundMethodAmiri, M. S., & Ramli, R. (2022) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.55730/1300-0632.3871 · Cited by 10
“The following equations express the torque for hip and knee while j = 1, 2, 3, 4 [32, 33].”
BackgroundSelf-citationAliman, N., Ramli, R., & Haris, S. M. (2021) · Lecture notes in mechanical engineering · doi:10.1007/978-981-16-0866-7_46 · Cited by 10
Self-citationPan, C., Wang, Y., Yang, S. X., Li, Z., & Xiao, J. (2024) · Machines · doi:10.3390/machines12100719 · Cited by 16
Phu, D. X., Van, M., & Nguyen, N. P. (2022) · European Journal of Control · doi:10.1016/j.ejcon.2022.100635 · Cited by 9
Liu, L., Shen, G., Wang, W., Li, X., & Zhu, Z. (2024) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/09596518241246825 · Cited by 8
Fu, Y., Zhou, X., Wan, B., & Yang, X. (2023) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062231152339 · Cited by 8
“Combining equations (8) with (20), we have”
BackgroundAlsaied, A., & Li, K. (2023) · International Conference on Robotics and Automation Engineering (ICRAE) · doi:10.1109/icrae59816.2023.10458492 · Cited by 8
“It is motivated by the biological behavior of swarms, animal herds, and bird flocks [19].”
BackgroundIdentification and Analysis of Human-Exoskeleton Coupling Parameters in Lower Extremities
Huang, C., Ji, S., Chen, Z., Sun, T., Guo, Q., & Yan, Y. (2024) · IEEE Transactions on Haptics · doi:10.1109/toh.2024.3375295 · Cited by 9
A Behavioral Study of Different Controllers and Algorithms in Real-Time Applications
Maheedhar, M., & Deepa, T. (2022) · IETE Journal of Research · doi:10.1080/03772063.2022.2153089 · Cited by 6
“For the lower limb exoskeleton, a PID controller with a genetic algorithm is presented [55].”
MethodSun, J., Wang, J., Yang, P., & Geng, Y. (2021) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-021-00166-3 · Cited by 5
Simulation studies on hybrid neuroprosthesis control strategies for gait at low speeds
de Sousa, A. C. C., & Bó, A. P. L. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102970 · Cited by 5
Lower-Limb Exoskeleton Systems for Rehabilitation and/or Assistance: A Review
Terrazas-Rodas, D., Rocca-Huaman, L., Ramirez-Amaya, C., & Alvarez-Rodríguez, A. E. (2022) · IEEE International IOT, Electronics and Mechatronics Conference (IEMTRONICS) · doi:10.1109/iemtronics55184.2022.9795739 · Cited by 5
Development of gait rehabilitation devices: a review of the literature
Al-Waeli, K. H., Ramli, R., Haris, S. M., & Zulkoffli, Z. (2023) · Mechanical Engineering Journal · doi:10.1299/mej.22-00450 · Cited by 4
Self-citationReview and Analysis of Platform-Related Performance of Rehabilitation Lower Limb Exoskeletons
Karami, H., Maludrottu, S., Vassallo, C., Laffranchi, M., & Michieli, L. D. (2023) · Actuators · doi:10.3390/act12110406 · Cited by 4
Pan, P., Hu, B., Feng, Y., Song, X., Zhang, Z., Cui, Z., & Tan, J. (2025) · International Journal of Production Research · doi:10.1080/00207543.2025.2588646 · Cited by 6
“Amiri, Ramli, and Ibrahim (2019) designed a hybrid optimisation method combining genetic algorithms and particle swarm optimisation to tune the parameters of a four-degree-of-freedom lower-limb exoskeleton PID controller, minimising joint control errors.”
InfluentialUse of adult anthropometric tables to estimate children body segment inertial parameters
Otmani, S., Michon, G., & Watier, B. (2023) · International Biomechanics · doi:10.1080/23335432.2023.2268686 · Cited by 4
“Additionally, they enhance our understanding of motor control of the computed model based on the BSIP, for example in the case of assistive technologies such as exoskeletons (Amiri et al. 2019).”
MethodOptimal Control Strategy of Electro-hydraulic Position Servo System Using Genetic Algorithm
Zhu, X., Zhang, B., & Rao, J. (2023) · Recent Patents on Mechanical Engineering · doi:10.2174/0122127976257342230927055915 · Cited by 4
Control Systems in Lower-limb Exoskeletons for Rehabilitation and/or Assistance: A Brief Review
Terrazas-Rodas, D., Rocca-Huaman, L., Ramirez-Amaya, C., Requejo-Rosales, J., Gutierrez-Atacusi, J., & Estacio-Cayetano, F. (2022) · International Conference on Smart Systems and Power Management (IC2SPM) · doi:10.1109/ic2spm56638.2022.9988843 · Cited by 4
Rehabilitation exoskeleton torque control based on PSO-RBFNN optimization
Li, J., Tai, Y., & Meng, F. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285453 · Cited by 4
“The purpose of the exoskeleton is to provide lower limb rehabilitation training for people with walking disabilities, and a single exoskeleton lower limb has a total of 4 degrees of freedom [13], namely hip flexion and extension degrees of freedom (active), hip internal rotation degrees of freedom (passive), knee flex…”
BackgroundHamza, M. F., & Abdullahi, A. M. (2026) · Modelling—International Open Access Journal of Modelling in Engineering Science · doi:10.3390/modelling7020054 · Cited by 3
Rehabilitation Exoskeletons: a Systematic Literature Review
Nacional, I. P., Robles, J. R., Reyes, J. B., Nacional, I. P., Hernández‐Simón, L. M., Nacional, I. P., Hernández, J. I. E. P., & Nacional, I. P. (2024) · Revista Mexicana de Ingeniería Biomédica · doi:10.17488/rmib.45.2.5 · Cited by 3
Belov, M. P., Truong, D. D., & Khoa, T. D. (2022) · IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering · doi:10.1109/elconrus54750.2022.9755511 · Cited by 3
“In [1], a method for adjusting the coefficients of the PID controller for the LLE with the GaPSo algorithm is presented to optimize the tracking error of the control system.”
MethodNikjoo, A. A., Arefnezhad, M., & Ghavifekr, A. A. (2023) · International Conference on Control, Instrumentation, and Automation · doi:10.1109/iccia61416.2023.10506373 · Cited by 3
Adaptive NN Force Loading Control of Electro-Hydraulic Load Simulator
Chen, Z., Hao, Y. X., Zhang, P., Shan, J., & Li, J. (2024) · Actuators · doi:10.3390/act13120471 · Cited by 3
Shenqi, G. A. O., Gao, S. F., Pan, W., & Wang, M. (2021) · Studies in Informatics and Control · doi:10.24846/v30i4y202105 · Cited by 3
Modelling and Analysis of Coupling Dynamics of a Lower Limb ExoskeletonPreprint
Yan, Y., Chen, Z., Huang, C., & Guo, Q. (2022) · Research Square · doi:10.21203/rs.3.rs-1165874/v1 · Cited by 3
Li, H., Mofid, O., Mobayen, S., Pan, T., Zhilenkov, A., & Chiu, H. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.09.025 · Cited by 2
Neural Network-Based Optimal Control of a Lower-limb Exoskeleton Robot
Huang, P., -, W. P. L. J. Z. Y., Li, Q., & Feng, Y. (2021) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm52023.2021.9536198 · Cited by 2
Cheng, X., Fong, J., Tan, Y. C., & Oetomo, D. (2022) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr55369.2022.9896596 · Cited by 2
Assessment of Wearable Lower Limb Rehabilitation Robot Dynamics: A Study on ROM Training Performance
Annisa, J., Mohamaddan, S., Zulkifli, M. A. A., Hazmi, H., & Leman, M. N. (2023) · IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA) · doi:10.1109/icsima59853.2023.10373433 · Cited by 1
“In the ROM condition, the performance of each joint was observed, while the other joints were fixed [23].”
MethodSahu, S., Acharya, D., Das, A. K., & Nayak, P. S. (2024) · International Journal of Dynamics and Control · doi:10.1007/s40435-024-01521-5 · Cited by 1
Wang, S., Tang, H. J., Ping, Z., Tan, Q., & Wang, B. (2025) · Applied Intelligence · doi:10.1007/s10489-025-06415-3 · Cited by 1
“Amiri et al. employed a hybrid optimization algorithm to design the PID controller of the lower extremity exoskeleton, thus improving the performance of the control system [31].”
Research progress on elbow joint rehabilitation robots
Li, M., Xu, F., Dian, W. A. N. G., & Jialing, X. U. (2025) · Journal of Zhejiang University (Medical Sciences) · doi:10.3724/zdxbyxb-2025-0307 · Cited by 1
Control system design for lower limb robotic exoskeleton using fuzzy-tuned PID
Rahmatillah, A., Adinda, A., Hanifah, U., Fadilah, M. H., Rulaningtyas, R., & Septanto, H. (2025) · AIP conference proceedings · doi:10.1063/5.0288618 · Cited by 1
Hamza, M. F., Isa, A. I., Alqahtani, A., & Rokbani, N. (2026) · Applied Sciences · doi:10.3390/app16147336 · Cited by 1
Graded Optimization of Upper Limb Exoskeleton Parts for Grid Operations
Hu, S., Zhou, X., & Bao, J. (2023) · IEEE Access · doi:10.1109/access.2023.3243942 · Cited by 1
“The literature [14] optimized the exoskeleton motion trajectory model by adaptive nondominated ranking genetic algorithm II (NSGA-II), the literature [15] designed a robust PID adaptive controller for exoskeleton based on improved particle swarm optimization (PSO) algorithm for nonlinear systems, and the literature [1…”
MethodAnnisa, J., Zulkifli, M. A. A., Leman, M. N., Mohamaddan, S., & Hazmi, H. (2024) · IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA) · doi:10.1109/icsima62563.2024.10675530 · Cited by 1
“Galvan et al. [9] designed a PID controller for WLLRs that exhibited good joint angle tracking performance despite disturbances.”
BackgroundPID controller parameters enhanced founded on Artificial Fish Swarm Algorithm
Kouassi, B. A., Zhang, Y., Kiki, M. J. M., & Ouattara, S. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1457/1/012003 · Cited by 1
Phu, D. X., & Nguyen, Q. H. (2021) · doi:10.1109/isee51682.2021.9418751 · Cited by 1
“From the applications of the PID model in [3-5], it can be seen that the classical type of PID is still an important tool in the design of modern controllers.”
BackgroundMethodInfluentialAn Evolutionarily Based Type-2 Fuzzy-PID for Multi-Machine Power System Stabilization
Ye, W., Ma, Z., Salah, M. M., & Shaker, A. (2023) · Mathematics · doi:10.3390/math11112500 · Cited by 1
A complete framework for personalised modeling and control of children's cerebral palsy
Otmani, S., Michon, G., & Watier, B. (2022) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids53995.2022.10000230
“2) Control of spasticity: PID schemes are widely used in the literature as an efficient method to control exoskeletons [15] and also human gaits in exoskeletons [16], [17].”
MethodDesign of a hip joint trajectory tracking controller for an exoskeleton
Soman, S., Sivanandan, K. S., Parameswaran, A. P., & Baiju, T. (2023) · AIP conference proceedings · doi:10.1063/5.0154111
Design of lower limb fitness exoskeleton based on ergonomics
Duan, L., Bao, C., Li, D., & Qian, X. (2024) · Highlights in Science Engineering and Technology · doi:10.54097/2r7crk19
“The exoskeleton walks synchronously in parallel with humans, and the degrees of freedom for the lower limb exoskeleton is designed from a bionic standpoint based on the degrees of freedom for the human lower limb [7].”
BackgroundIqbal, A., & Joshi, D. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4832910
Identification of muscle-activation-dependent human-exoskeleton coupling parameters
Huang, C., Ji, S., Sun, T., Chen, Z., Guo, Q., & Yan, Y. (2024) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2024.102946
Chen, Z., Li, T., Yan, Y., & Guo, Q. (2024) · International Conference on Information Science and Technology · doi:10.1109/icist63249.2024.10805306
An Optimal PID Controller for Artificial Knee Exoskeleton Devices
Acharya, D., Roy, S., Debnath, B., & Das, J. C. (2025) · Devices for Integrated Circuit (DevIC) · doi:10.1109/devic63749.2025.11012404
“For an exoskeleton model, the authors in [6] suggested a hybrid optimiser that combines particle swarm optimisation (PSO) with genetic algorithms (GA).”
Mechanical structure design of lower limb rehabilitation training robot
Xu, W., & Wang, J. (2025) · International Conference on Computer, Artificial Intelligence and Control Engineering (CAICE) · doi:10.1145/3727648.3727699
Güler, S. (2025) · International Journal of Non-Linear Mechanics · doi:10.1016/j.ijnonlinmec.2025.105198
Control Schemes for Lower Limb Exoskeleton: A Systematic Review
Minhas, H. S., Umar, U., Sattar, N. Y., Khan, A., & Ahmad, N. (2025) · International Conference on Emerging Technologies in Electronics, Computing and Communication (ICETECC) · doi:10.1109/icetecc65365.2025.11070287
“Another paper explains how to use a hybrid genetic algorithm and particle swarm optimization to tune a PID controller for a lower limb exoskeleton [18].”
Period Motion Tracking of Lower Limb Exoskeleton: A New Time-Independent Control Approach
Zhang, J., Shu, Z., & Xu, J. (2025) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2025.3610977
“In the meantime, classic PID controllers with various types of model compensation have also been widely studied to enable exoskeletons to follow the predefined gait trajectories [5], [6], [7].”
Elstohy, M., & Gwak, K. (2026) · International Journal of Dynamics and Control · doi:10.1007/s40435-026-02026-z · Cited by 1
“…methods for exoskeletons exhibit notable limitations: PID control lacks robustness against dynamic uncertainties, resulting in poor tracking [18, 19]; sensitivity amplifica-tion demands precise system models, impractical due to patient variability [20, 21]; sliding mode control (SMC) introduces…”
Hip exoskeleton controller design: a comprehensive review for people with leg deformities
Neogi, B., Chakraborty, P., Das, S., Bhattacharjee, S., Peng, S. L., Dey, R., & Mahajan, R. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-40379-8.00016-8
Embodied intelligence perspectives on lower limb rehabilitation exoskeleton control: A review
Zhao, L., Liu, D., Zhang, H., He, L., & Chen, J. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.111318
Adaptive Fully-Actuated Control for Lower Limb Exoskeletons with High-Order Disturbance Compensation
Kou, J., Xia, Y., Shen, X., Yang, Z., Wang, Y., Shi, Y., Zuo, Z., & Xie, F. (2026) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2026.125819
Nishanth, F. P., Dash, S. K., Mahapatro, S. R., & Naik, M. K. (2026) · Journal of Control and Decision · doi:10.1080/23307706.2026.2665333
Gao, M., Wang, H., Wang, Y., Jiang, D. M., Zhang, W., Feng, W., & Zhao, F. (2026) · Electronics · doi:10.3390/electronics15132878
Development and control of a robotic lower limb exoskeleton for pediatric users
Cruz-Cortes, A., Ballesteros, M., & Ortiz, D. C. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.111992
A novel SOSMC-based COA-COOT approach for a multi-joint lower extremity exoskeleton system
Roy, R. G., Lakhekar, G. V., Bhowmik, D., & Tanveer, M. H. (2026) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2026.2723088
Metadata
- Authors
- Amiri, M. S., Ramli, R., & Ibrahim, M. F.
- Affiliations
- National University of Malaysia (MY)
- Corresponding author
- Ramli, Rizauddin
- Venue
- Applied Mathematical Modelling
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 72
- Pages
- 17-27
- ISSN
- 0307-904X (ISSN-L)
- OpenAlex
- W2921821198
- Cited by
- 93
- References
- 33
- Citations by year
- 2026: 11 · 2025: 12 · 2024: 13 · 2023: 16 · 2022: 11 · 2021: 18 · 2020: 9 · 2019: 3
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (vor, 1461 d)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- Applied Mathematical Modelling (publishedVersion)
- Funders
- Universiti Kebangsaan Malaysia
- Ministry of Higher Education, Malaysia (FRGS/1/2017/TK03/UKM/02/4)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Computer Science › Artificial Intelligence › Metaheuristic Optimization Algorithms Research
- Keywords
- PID controller tuning, lower limb exoskeleton, hybrid genetic algorithm and particle swarm optimization, controller tuning, feedback control, trajectory tracking, joint control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.