Cited by 140Refrigeration and Air Conditioning TechnologiesAdsorption and Cooling SystemsBuilding Energy and Comfort Optimization

An experimental study on the operating performance of a novel reverse-cycle hot gas defrosting method for air source heat pumps

Wenju, Hu, Yiqiang, Jiang, Minglu, Qu, Long, Ni, Yang, Yao, Shiming, Deng·2011·Applied Thermal Engineering

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2010.09.024

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Wenju, H., Yiqiang, J., Minglu, Q., Long, N., Yang, Y., & Shiming, D.
Affiliations
Harbin Institute of Technology (CN)
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2011-02
Volume
31
Issue
2-3
Pages
363-369
ISSN
1359-4311 (ISSN-L)
OpenAlex
W1967235977
Cited by
140
References
0
Citations by year
2026: 3 · 2025: 15 · 2024: 16 · 2023: 6 · 2022: 16 · 2021: 6 · 2020: 12 · 2019: 12 · 2018: 9 · 2017: 13 · 2016: 8 · 2015: 8 · 2014: 6 · 2013: 5 · 2012: 2
FWCI
6.09
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Thermal Engineering (publishedVersion)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
Funders
  • National Natural Science Fund of China (50606007)
  • Hong Kong Research Grant Council (B-Q05R)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
air-source heat pump, thermal energy storage, defrosting time, indoor thermal environment, system reliability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review