Experimental study on frosting control of mobile air conditioning system with microchannel evaporator
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The optimum installation position of the temperature sensor on the downstream surface of MCHX is the position with low and uniform temperature distribution, high airflow rate, and dry fin surface.
“the optimum installation position of the temperature sensor on the downstream surface of MCHX should be the position with low and uniform temperature distribution, high airflow rate, and dry fin surface.”
Poor drainage of a microchannel evaporator leads to the failure mode of frosting protection of the temperature sensor.
“To address the problem that the poor drainage of the microchannel evaporator would lead to the failure mode of the frosting protection of the temperature sensor”
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 16 · Cited by 20
- Authors
- Qu, X., Shi, J., Qi, Z., & Chen, J.
- Affiliations
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Qu, Xiaohua
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2011-10
- Volume
- 31
- Issue
- 14-15
- Pages
- 2778-2786
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W1966104080
- Cited by
- 20
- References
- 16
- Citations by year
- 2025: 3 · 2023: 2 · 2022: 3 · 2021: 2 · 2019: 1 · 2018: 2 · 2017: 1 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 2
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Thermal Engineering (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- frost protection, automotive air conditioning, microchannel evaporator, coefficient of performance, temperature swing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review