The DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.
Performance analysis and working fluid selection for ejector refrigeration cycle
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There are currently two ways of combining electrical energy generation and cooling system: (1) the use of ejector, 185,189 (2) turbine driven compressor, 190-192”
From Energy system and resource utilization in space: A state-of-the-art review (2024) · cites this paper as [189]
In the citing paper
“Besides, the CBC system, which uses CO2 as the working fluid, is lower than that of the CBC with He-Xe as the working fluid at low pressure. 189”
From Energy system and resource utilization in space: A state-of-the-art review (2024) · cites this paper as [189]
Citations
Cites
A 1-D analysis of ejector performance
Huang, B., Chang, J.-S., Wang, C. P., & Petrenko, V. A. (1999) · International Journal of Refrigeration · doi:10.1016/s0140-7007(99)00004-3 · Cited by 1,089
Working fluids for low-temperature organic Rankine cycles
SALEH, B., KOGLBAUER, G., WENDLAND, M., & FISCHER, J. (2007) · Energy · doi:10.1016/j.energy.2006.07.001 · Cited by 1,045
Self-citationWorking fluids for high-temperature organic Rankine cycles
Lai, N. A., Wendland, M., & Fischer, J. (2011) · Energy · doi:10.1016/j.energy.2010.10.051 · Cited by 1,032
An Investigation of Ejector Design by Analysis and Experiment
Keenan, J. H., Neumann, E. P., & Lustwerk, F. (1950) · Journal of Applied Mechanics · doi:10.1115/1.4010131 · Cited by 656
Ejector refrigeration: A comprehensive review
Besagni, G., Mereu, R., & Inzoli, F. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.08.059 · Cited by 519
Review of recent developments in advanced ejector technology
Elbel, S. W., & Lawrence, N. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.10.031 · Cited by 316
Evaluation of steam jet ejectors
El-Dessouky, H., ETTOUNEY, H. M., Alatiqi, I. M., & Al-Nuwaibit, G. (2002) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/s0255-2701(01)00176-3 · Cited by 192
Chen, J., Havtun, H., & Palm, B. E. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.12.034 · Cited by 173
Theoretical analysis of ejector refrigeration system performance under overall modes
Chen, W., Shi, C., Zhang, S., Chen, H., Chong, D., & Yan, J. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.01.103 · Cited by 172
Yapıcı, R., Ersoy, H. K., Aktoprakoğlu, A., Halkacı, H. S., & Yiğit, O. (2008) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.02.010 · Cited by 158
Performance characteristics of HCFC-123 ejector refrigeration cycles
Sun, D., & Eames, I. W. (1996) · International Journal of Energy Research · doi:10.1002/(sici)1099-114x(199610)20:10<871::aid-er201>3.0.co;2-4 · Cited by 148
Screening of working fluids for the ejector refrigeration system
Chen, J., Havtun, H., & Palm, B. E. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.07.016 · Cited by 118
Yu, J., Ren, Y., Chen, H., & Li, Y. (2006) · Energy Conversion and Management · doi:10.1016/j.enconman.2006.10.009 · Cited by 106
CFD study of a variable area ratio ejector using R600a and R152a refrigerants
Varga, S., Lebre, P. S., & Oliveira, A. C. (2012) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2012.10.016 · Cited by 103
Energy and exergy efficiency analysis of solar driven ejector–compressor heat pump cycle
Yan, G. F., Bai, T., & Yu, J. (2016) · Solar Energy · doi:10.1016/j.solener.2015.12.021 · Cited by 77
Efficiency analysis of alternative refrigerants for ejector cooling cycles
Gil, B., & Kasperski, J. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.01.056 · Cited by 61
A study of working fluids for heat driven ejector refrigeration using lumped parameter models
Besagni, G., Mereu, R., Leo, G. D., & Inzoli, F. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.06.015 · Cited by 59
Mansour, R. B., Ouzzane, M., & Aidoun, Z. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.04.010 · Cited by 55
Thermodynamic investigation of a booster-assisted ejector refrigeration system
Zhao, H., Zhang, K., Wang, L., & Han, J. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.05.067 · Cited by 52
Experimental study of the behavior of a hybrid ejector-based air-conditioning system with R134a
Wang, H., Cai, W., Wang, Y., Yan, J. X., & Wang, L. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.01.010 · Cited by 48
Experimental study on a multi-evaporator refrigeration system with variable area ratio ejector
Li, C., Yan, J. X., Li, Y., Cai, W., Chen, L., & Chen, H. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.04.006 · Cited by 48
Analysis for the ejector used as expansion valve in vapor compression refrigeration cycle
Wang, F., Li, D. Y., & Zhou, Y. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.11.095 · Cited by 44
Yan, G. F., Bai, T., & Yu, J. (2015) · Energy · doi:10.1016/j.energy.2015.11.067 · Cited by 38
Readdressing working fluid selection with a view to designing a variable geometry ejector
Varga, S., Lebre, P. S., & Oliveira, A. C. (2013) · International Journal of Low-Carbon Technologies · doi:10.1093/ijlct/ctt026 · Cited by 34
Research works printed but not linked: 1
- J.M. Calm, G.C. Hourahan, Physical, safety, and environmental data summary for current and alternative refrigerants, ID: 915, in: Proceedings of the 23rd International Congress of Refrigeration, Prague, Czech Republic, 2011, pp. 1–22.
Cited by
A comprehensive review of ejector design, performance, and applications
Tashtoush, B. M., Al-Nimr, M. A., & Khasawneh, M. A. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.185 · Cited by 386
Ghaebi, H., Parikhani, T., Rostamzadeh, H., & Farhang, B. (2017) · Energy · doi:10.1016/j.energy.2017.07.154 · Cited by 215
Eveloy, V. C., & Ayou, D. S. (2019) · Energies · doi:10.3390/en12020235 · Cited by 134
“However, ejector-based refrigeration systems are presently receiving considerable attention for space cooling due to their construction simplicity with no moving parts or seals, low maintenance requirements, low-grade renewable/waste heat use and energy consumption reduction potential, and compatibility with environme…”
BackgroundGhaebi, H., Parikhani, T., Rostamzadeh, H., & Farhang, B. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.11.067 · Cited by 119
Saleh, B. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.06.018 · Cited by 105
Self-citation
Metadata
- Authors
- Saleh, B.
- Affiliations
- Taif University (SA)
- Corresponding author
- Saleh, B.
- ORCID
- Saleh, B.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 107
- Pages
- 114-124
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2462898646
- Cited by
- 104
- References
- 25
- Citations by year
- 2026: 6 · 2025: 11 · 2024: 8 · 2023: 16 · 2022: 9 · 2021: 8 · 2020: 11 · 2019: 12 · 2018: 11 · 2017: 9 · 2016: 3
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Applied Thermal Engineering (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Thermodynamic Systems and Engines
- Keywords
- ejector refrigeration cycle, working fluid selection, low-grade heat utilization, coefficient of performance, entrainment ratio, R245ca, refrigerant thermodynamic properties
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.