CoChat

Effect of hydraulic diameter and aspect ratio on single phase flow and heat transfer in a rectangular microchannel

Open access
Sahar, Amirah M., Wissink, Jan, Mahmoud, Mohamed M., Karayiannis, Tassos G., Ashrul Ishak, Mohamad S. · 2017 · Applied Thermal Engineering
Cited by 172

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

The effect of aspect ratio and hydraulic diameter on single phase flow and heat transfer in a single microchannel was investigated numerically and the results are presented in this paper. Previously, many studies in literature investigating the effect of geometrical parameters reached contradictory conclusions leaving some phenomena unexplained. Additionally, most researchers studied the effect of channel geometry by varying the channel height for a constant channel width or varying the width for a constant height. This means that the hydraulic diameter and aspect ratio vary simultaneously, which makes it difficult to identify the relative importance of the aspect ratio and the hydraulic diameter. In the present study, the effect of hydraulic diameter was studied by varying the channel width and depth while keeping the aspect ratio constant. The range of hydraulic diameters was 0.1–1 mm and the aspect ratio was fixed at 1. In the second set of simulations, the aspect ratio ranged from 0.39 to 10 while the hydraulic diameter was kept constant at 0.56 mm. The simulations were performed using the CFD software package ANSYS Fluent 14.5. The geometry investigated in this study includes symmetrical cylindrical inlet and outlet plenums and a microchannel. The fluid entered and left the channel vertically from the top in a direction normal to the channel axis. The dimensions of the inlet/outlet plenums (diameter and height measured from the channel bottom surface) were kept constant while the width and depth of the channel were varied. The simulations were conducted for a range of Reynolds numbers (Re = 100–2000) and water was used as the working fluid. A three dimensional thin wall model was used to avoid conjugate heat transfer effects. A constant heat-flux boundary condition was applied at the bottom and vertical side walls of the channel, while the upper wall was considered adiabatic. The friction factor was found to decrease slightly with aspect ratio up to AR ≈ 2 after which it increased with increasing aspect ratio. The results demonstrated that the slope of the velocity profile at the channel wall changes significantly with aspect ratio for AR > 2. The effect of the aspect ratio and hydraulic diameter on the dimensionless hydrodynamic entry length is not significant. Also, the aspect ratio does not affect the heat transfer coefficient while the dimensionless Nusselt number increases with increasing hydraulic diameter. The friction factor was found to increase with increasing hydraulic diameter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2017.01.018

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

Metadata

Authors
Sahar, A. M., Wissink, J., Mahmoud, M. M., Karayiannis, T. G., & Ashrul Ishak, M. S.
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2017-03
Volume
115
Pages
793-814
ISSN
1359-4311 (ISSN-L)
OpenAlex
W2571139366
Cited by
172
References
20
FWCI
10.97
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.