Experimental research on heat and mass transfer characteristics of cross-flow closed-type heat-source tower
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Frost deposition on the evaporator surface in winter is a major obstacle to air source heat pump operation.
“However, frost deposition on the evaporator surface in the winter season is a major obstacle of the heat pump operation [1 -4].”
From Prediction of the frost growth and performance change of air source heat pump system under various frosting conditions (2019) · cites this paper as [4]
Cites
Frost formation with varying environmental parameters
Jones, B. W., & Parker, J. D. (1975) · Journal of Heat Transfer · doi:10.1115/1.3450350 · Cited by 171 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Huang, S.-F., Zuo, W., Lu, H.-X., Liang, C.-H., & Zhang, X. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.11.050 · Cited by 90 · see citing works
“Song et al.[14] conducted a similar study where a 24 closed-type heat-source tower was used and found that the mass transfer coefficient had a magnitude equal to that 25 of the liquid desiccant dehumidifier.”
ResultChung, Y., Yoo, J. W., Kim, G. T., & Kim, M. S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.10.085 · Cited by 81 · see citing works
Huang, S.-F., Yu, H.-F., Zhang, M.-X., Qu, H., Wang, L., Zhang, C., Yuan, Y.-B., & Zhang, X.-S. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121163 · Cited by 73 · see citing works
Chung, Y., Na, S., Choi, J., & Kim, M. S. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.04.002 · Cited by 36 · see citing works
Zhang, Y., He, F., Zhang, G.-M., Qu, X.-H., & Tian, M.-C. (2022) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2022.123416 · Cited by 32 · see citing works
Hu, Z.-C., Geng, S., Huang, Y.-F., Ge, F., & Wang, Y.-C. (2021) · doi:10.1016/j.enbuild.2021.110752 · Cited by 31
Su, W., Li, W., Sun, B., & Zhang, X. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.11.078 · Cited by 31 · see citing works
Xiao, H., Song, P.-Y., Wang, B.-L., Li, Z.-M., Shi, W.-X., Yang, Z.-X., Li, X.-T., Huang, Y.-S., & Liang, Z. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110858 · Cited by 29
Self-citationSong, P.-Y., Xiao, H., Wang, B.-L., Shi, W.-X., Li, X.-T., & Zhang, G.-H. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.03.089 · Cited by 26
Self-citationZendehboudi, A., Song, P., & Li, X.-T. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.11.003 · Cited by 23 · see citing works
Self-citationStudy on thermal performance of new finned heat exchange tube bundles in cooling tower
Zhao, R., Shi, B., Zhao, X.-H., Zhang, L., Xu, W.-G., Yu, Z., Fang, J.-M., Ji, Y.-X., Hu, Y.-Y., & Bao, B.-G. (2021) · doi:10.1016/j.ijthermalsci.2021.107064 · Cited by 21
Zhang, Y., Zhang, G.-M., Qu, X.-H., & Tian, M.-C. (2020) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.120347 · Cited by 21 · see citing works
Performance evaluation of heating tower heat pump systems over the world
Huang, S.-F., Ye, Y.-Y., Han, X., Zuo, W., Zhang, X., & Jiang, L. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.03.003 · Cited by 21
Experimental investigation on closed-type heating tower using glycerol solution
Song, P.-Y., Xiao, H., Shi, W.-X., Li, X.-T., Wang, B.-L., Li, Z.-M., Zhang, Y., & Zhong, H.-A. (2019) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2018.12.004 · Cited by 18
Self-citationDesign method for heating towers used in vapor-compression heat pump systems
Huang, S.-F., Xie, L.-Y., Lu, L., & Zhang, X. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107532 · Cited by 15 · see citing works
Guan, B., Liu, X.-H., & Zhang, T. (2021) · doi:10.1016/j.ijheatmasstransfer.2020.120614 · Cited by 15
Liu, Q., Li, N., Duan, J., Song, M.-Y., & Shi, F. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.110568 · Cited by 14
Huang, S.-F., Wang, L., Xie, L.-Y., Liu, J., & Zhang, X.-S. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.108060 · Cited by 12 · see citing works
Zhou, D., Zhang, Y., Zhang, Y.-C., Wu, Y.-T., & Zhang, G.-M. (2024) · The Physics of Fluids · doi:10.1063/5.0203373 · Cited by 11 · see citing works
Liu, J.-N., Zhang, L.-X., Lin, Z.-H., Gao, M.-C., & Chen, H. (2019) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2019.03.002 · Cited by 10
Reconciling thermal performance and power-saving performance of counter-flow spray heating towers
Cui, H., Ye, B.-C., Wang, L., Li, N.-P., & Xing, D.-M. (2021) · doi:10.1016/j.egyr.2021.03.006 · Cited by 9
Qu, H., Wang, L., Zhang, X., Che, C., Zhang, X.-S., & Huang, S.-F. (2024) · Fluid Phase Equilibria · doi:10.1016/j.fluid.2024.114183 · Cited by 7
Ding, S.-J., Zhang, Y., Zhou, D., Zhang, Z., Tian, M.-C., & Zhang, G.-M. (2025) · International Journal of Heat and Fluid Flow · doi:10.1016/j.ijheatfluidflow.2025.109761 · Cited by 6 · see citing works
Shen, X.-H., Li, N.-P., & A, Y. (2021) · Energies · doi:10.3390/en14071816 · Cited by 5
Liu, P., Xiao, D., Lu, J., Li, Y., Yang, S., & Liu, X. (2025) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2025.125810 · Cited by 4 · see citing works
Deicing performance analysis of the solution regenerator unit using freeze concentration
Han, C., Chen, X., Wang, Y., & Ni, L. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.124194 · Cited by 4
Performance investigation of a multi-connected heating tower heat pump system
Hu, H., Ji, J., Xie, L.-Y., Le, Y.-F., & Zhang, X. (2022) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2021.12.027 · Cited by 3
Experimental Study on a Heat-Source Tower under Different Configurations
Cheng, J., Li, N.-P., Cui, H., & Li, T. (2020) · doi:10.1061/(asce)ey.1943-7897.0000666 · Cited by 3
Li, L., Zhang, H.-F., Zhang, Z.-T., Qi, F., Tu, Q., Wu, H.-W., Yang, J.-L., Zhang, X., & He, M. (2025) · International journal of refrigeration · doi:10.1016/j.ijrefrig.2025.06.013 · Cited by 2 · see citing works
A Review on the Heat-Source Tower Heat Pump Systems in China
Yao, X., Feng, R., & Li, X.-Z. (2024) · Energies · doi:10.3390/en17102389 · Cited by 2
Self-citationThermodynamic Investigation on the Performance of Closed Wet Cooling Tower
Fang, J.-M., Zhao, X.-H., Zhang, L., Bu, S., Yu, Z., Xu, W.-G., Hu, Y.-Y., Shan, Y., & Li, Y. (2021) · Journal of Thermal Science and Engineering Apllications · doi:10.1115/1.4051633 · Cited by 2
Ding, S.-J., Zhang, Y., Zhang, Z., Zhang, G.-M., & Tian, M.-C. (n.d.) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2025.127787 · Cited by 2
Chen, B., Ma, M., & Zhang, X. (2024) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2024.105394 · Cited by 1
Thermal performance of a Divided-flow type Shell and Tube Compact Heat Exchanger
Nagaraj, S., Nagaraj, A., & Karthik, N. (2020) · Journal of Physics, Conference Series · doi:10.1088/1742-6596/1473/1/012031
- Authors
- Song, P., Wang, B., Li, X., & Shi, W.
- Affiliations
- Tsinghua University (CN)
- Corresponding author
- Shi, Wenxing
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2018-05
- Volume
- 135
- Pages
- 289-303
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2793499091
- Cited by
- 34
- References
- 29
- Citations by year
- 2025: 4 · 2024: 6 · 2023: 2 · 2022: 2 · 2021: 6 · 2020: 5 · 2019: 4 · 2018: 5
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Thermal Engineering (publishedVersion)
- Funders
- China National Key R&D Program (2016YFC0700304)
- Innovative Research Group of the National Natural Science Foundation of China (51521005)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Keywords
- heat and mass transfer coefficients, antifreeze solutions, liquid desiccant dehumidifier, space heating, low ambient temperature
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review