Recent advancements on thermal management and evaluation for data centers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
As the hub of data storage, network communication, and computation station, data center has been inseparable from the development of each social sector. With the increasing demand on the data communication and calculation, the size and number of data centers are experiencing a dramatic expansion. As a critical sequel to the continuous deploying of data centers, the tremendous energy consumption has become a worldwide problem. Compared to the energy utilizing in office facilities, the energy demand per square meter has been increased by 100 times for data centers during recent years. To improve the energy utilizing efficiency of data centers, various design and operation method have been proposed. However, there are still short of statistical studies on the thermal management and evaluation of data centers and associated cooling systems. This paper presents a state-of-the-art review on the research and development in this field, covering the topics of thermal management techniques and associated evaluation metrics. In addition, energy conservation strategies and optimization methods account for the safety operating of data centers are also discussed in detail. Finally, guidelines on research and strategies for thermal management and evaluation in data centers are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yuventi, J., & Mehdizadeh, R. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.04.015 · Cited by 114
Cited by
Umair, M. M., Zhang, Y., Iqbal, K., Zhang, S., & Tang, B. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.11.017 · Cited by 852
Self-citationHuang, P., Copertaro, B., Zhang, X., Shen, J., Löfgren, I., Rönnelid, M., Fahlen, J., Andersson, D., & Svanfeldt, M. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114109 · Cited by 414
Zhu, H., Zhang, D., Goh, H. H., Wang, S., Ahmad, T., Mao, D., Liu, T., Zhao, H., & Wu, T. (2023) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.104322 · Cited by 164
Du, Z., & Lu, R. (2025) · Batteries · doi:10.3390/batteries11060204 · Cited by 58
Metadata
- Authors
- Zhang, K., Zhang, Y., Liu, J., & Niu, X.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 142
- Pages
- 215-231
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2836517248
- Cited by
- 115
- References
- 1
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advancements on thermal management and evaluation for data centers. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2018.07.004
- The paper
- Zhang, K., Zhang, Y., Liu, J., & Niu, X. (2018). Recent advancements on thermal management and evaluation for data centers. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2018.07.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.