Experimental analysis of the effective thermal conductivity enhancement of PCM using finned tubes in high temperature bulk tanks
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Solar cooling is a promising solution to overcome the high energy demand of buildings. Nevertheless, the time dependent nature of the solar source leads to the need of storage systems in order to better match the energy demand and supply. For this purpose, thermal energy storage was considered during last decades as the optimal solution at commercial scale. Latent thermal energy storage offers higher energy densities together with more constant outlet temperature than sensible heat storage, but the low thermal conductivities of PCMs represents the main drawback which limits its applicability. Several studies based on heat transfer enhancement techniques applied in latent thermal energy storage have already been performed. Specifically, the technique of adding fins in storage tanks, which is the most known and studied. However, there are few experimental studies at pilot plant scale focused on this technique and less on the analysis of the heat transfer enhancement through the parameter effective thermal conductivity. This paper presents an experimental study where this parameter is determined and compared using of two identical latent storage tanks, one with 196 transversal squared fins and another one without fins. In this case, hydroquinone was selected as PCM. A set of six experiments was performed at pilot plant of the University of Lleida (Spain), combining three different HTF flow rates and two temperature gradients between HTF inlet temperature and initial PCM temperature. Experimental results showed that the addition of fins can increase the effective thermal conductivity between 4.11% and 25.83% comparing the experiment with highest and lowest thermal power supplied to the PCM, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tiari, S., Qiu, S., & Mahdavi, M. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.10.053 · Cited by 296
Cited by
Wang, X., Li, W., Luo, Z., Wang, K., & Shah, S. P. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.111923 · Cited by 493
A review of technologies and applications on versatile energy storage systems
Zhang, Z., Ding, T., Zhou, Q., Sun, Y., Qu, M., Zeng, Z., Ju, Y., Li, L., Wang, K., & Chi, F. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111263 · Cited by 489
Review on micro/nano phase change materials for solar thermal applications
Qiu, L., Ouyang, Y., Feng, Y., & Zhang, X. (2019) · Renewable Energy · doi:10.1016/j.renene.2019.03.088 · Cited by 255
Han, D., Guene Lougou, B., Xu, Y., Shuai, Y., & Huang, X. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114674 · Cited by 155
Reyes, A., Henríquez-Vargas, L., Vásquez, J., Pailahueque, N., & Aguilar, G. (2020) · Renewable Energy · doi:10.1016/j.renene.2019.06.007 · Cited by 23
Metadata
- Authors
- Gil, A., Peiró, G., Oró, E., & Cabeza, L. F.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 142
- Pages
- 736-744
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2883891655
- Cited by
- 90
- References
- 1
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental analysis of the effective thermal conductivity enhancement of PCM using finned tubes in high temperature bulk tanks. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2018.07.029
- The paper
- Gil, A., Peiró, G., Oró, E., & Cabeza, L. F. (2018). Experimental analysis of the effective thermal conductivity enhancement of PCM using finned tubes in high temperature bulk tanks. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2018.07.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.