Abstract To overcome the temperature increase of battery along the flow direction of coolant in cylindrical lithium-ion battery module, a composite thermal management system integrated with mini-channel liquid cooling and air cooling is proposed. The computational fluid dynamics model of battery module is validated using the experiment results to investigate the effects of inlet flow rate of water, amount of cooling tube and mini-channel, tube space, water flow direction, and spacer combination on the thermal performance of mini-channel liquid cooling at 4 C discharge rate. When air cooling is integrated with mini-channel liquid cooling, the corresponding thermal performance of the composite system is analyzed. The results show that the maximum temperature and temperature difference decrease with an increase in the water inlet flow rate with a significant rise of power consumption. When the water inlet flow rate is 3 × 10−4 kg⋅s−1, the increasing amount of the cooling tube and mini-channel could slightly improve the cooling performance. If the cases with suitable values of the tube space, flow direction, and spacer combination are adopted, the temperature difference would remain within 4.13 K, and the maximum temperature decreases to 304.98 K. Moreover, the extra air cooling at the velocity of 4 m⋅s−1 could reduce the maximum temperature and the temperature difference of battery module dropped by 2.22 K and 2.04 K at 80% DOD. More importantly, the maximum temperature difference could be manipulated within 5.0 K when the fan was automatically controlled according to the temperature of the battery module.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.applthermaleng.2020.115331

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 238

Metadata

Authors
Yang, W., Zhou, F., Zhou, H., Wang, Q., & Kong, J.
Venue
Applied Thermal Engineering
Publisher
Elsevier BV
Published
2020-07
Volume
175
Pages
115331
ISSN
1359-4311 (ISSN-L)
OpenAlex
W3016697992
Cited by
238
References
0
FWCI
10.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermal performance of cylindrical lithium-ion battery thermal management system integrated with mini-channel liquid cooling and air cooling. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2020.115331
The paper
Yang, W., Zhou, F., Zhou, H., Wang, Q., & Kong, J. (2020). Thermal performance of cylindrical lithium-ion battery thermal management system integrated with mini-channel liquid cooling and air cooling. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2020.115331

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.