Leak detection in a subcritical boiler
The DOI matches its Crossref record; the references it cites are not checked yet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 16
Research works printed but not linked: 17
- S. Pfeuffer, Update: Benchmarking Boiler Tube Failures, vol. 2019, Power Magazine, 2009.
- F.D. Lang, D.A. Rodgers, L.E. Mayer, Detection of tube leaks and their location using input/loss methods, in: ASME 2004 Power Conference, American Society of Mechanical Engineers Digital Collection, Baltimore, MD, 2008, pp. 1-10. · doi:10.1115/power2004-52027
- Tian, 2017, Online performance monitoring platform based on the whole process models of subcritical coal-fired power plants, Appl. Therm. Eng., 124, 1368, 10.1016/j.applthermaleng.2017.06.112 · doi:10.1016/j.applthermaleng.2017.06.112
- Cai, 2009, Online monitoring the performance of coal-fired power unit: a method based on support vector machine, Appl. Therm. Eng., 29, 2308, 10.1016/j.applthermaleng.2008.11.012 · doi:10.1016/j.applthermaleng.2008.11.012
- Zhang, 2015, Power station boiler furnace water-cooling wall tube leak locating method based on acoustic theory, Appl. Therm. Eng., 77, 12, 10.1016/j.applthermaleng.2014.12.015 · DOI
- Flynn, 2003, Thermal power plant simulation and control, IET
- Martins, 1995, A new instrument for radiation heat flux measurement—analysis and parameter selection, Heat Recovery Syst. CHP, 15, 787, 10.1016/0890-4332(94)00082-V · doi:10.1016/0890-4332(94)00082-v
- Afgan, 1998, Boiler tube leakage detection expert system, Appl. Therm. Eng., 18, 317, 10.1016/S1359-4311(97)00054-9 · doi:10.1016/s1359-4311(97)00054-9
- Sun, 2002, Efficient model-based leak detection in boiler steam-water systems, Comput. Chem. Eng., 26, 1643, 10.1016/S0098-1354(02)00147-3 · DOI · Paper page
- Sun, 2005, An improved PCA method with application to boiler leak detection, ISA Trans., 44, 379, 10.1016/S0019-0578(07)60211-0 · DOI · Paper page
- Widarsson, 2008, Bayesian network-based early-warning for leakage in recovery boilers, Appl. Therm. Eng., 28, 754, 10.1016/j.applthermaleng.2007.06.016 · doi:10.1016/j.applthermaleng.2007.06.016
- Li, 2009, Model-based monitoring and fault diagnosis of fossil power plant process units using Group Method of Data Handling, ISA Trans., 48, 213, 10.1016/j.isatra.2008.10.014 · doi:10.1016/j.isatra.2008.10.014
- Jiang, 2014, A data reconciliation based framework for integrated sensor and equipment performance monitoring in power plants, Appl. Energy, 134, 270, 10.1016/j.apenergy.2014.08.040 · doi:10.1016/j.apenergy.2014.08.040
- Rostek, 2015, Early detection and prediction of leaks in fluidized-bed boilers using artificial neural networks, Energy, 89, 914, 10.1016/j.energy.2015.06.042 · DOI · Paper page
- Hundi, 2020, Comparative studies among machine learning models for performance estimation and health monitoring of thermal power plants, Appl. Energy, 265, 114775, 10.1016/j.apenergy.2020.114775 · DOI
- Chen, 2011, Using SVM based method for equipment fault detection in a thermal power plant, Comput. Ind., 62, 42, 10.1016/j.compind.2010.05.013 · DOI · Paper page
- Geman, 1992, Neural networks and the bias/variance Dilemma, Neural Comput., 4, 1, 10.1162/neco.1992.4.1.1 · DOI · Paper page
Metadata
- Authors
- Panday, R., Indrawan, N., Shadle, L. J., & Vesel, R. W.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 185
- Pages
- 116371
- ISSN
- 1359-4311
- Cited by
- 16
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (am, 348 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Leak detection in a subcritical boiler. https://app.cochat.ai/papers/10.1016/j.applthermaleng.2020.116371
- The paper
- Panday, R., Indrawan, N., Shadle, L. J., & Vesel, R. W. (2021). Leak detection in a subcritical boiler. Applied Thermal Engineering. https://doi.org/10.1016/j.applthermaleng.2020.116371
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.