Experimental investigation on vapor injection defrosting performance of quasi-two-stage compression air source heat pump with flash tank
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Compared to the research conducted by scholars [35,40-44,46,87,88], this approach considers the overall improvement of the frosting and defrosting process for the ASHP, effectively combining proactive defrosting with efficient defrosting.
“Compared to the research conducted by scholars [35,40 -44,46,87,88], this approach considers the overall improvement of the frosting and defrosting process for the ASHP, effectively combining proactive defrosting with efficient defrosting.”
From Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification (2024) · cites this paper as [40]
Cites
Review on improvement for air source heat pump units during frosting and defrosting
Song, M., Deng, S., Dang, C., Mao, N., & Wang, Z. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.022 · Cited by 384 · see citing works
Tso, C. P., Cheng, Y. C., & Lai, A. C. K. (2006) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2005.04.009 · Cited by 75 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Enhancing heat-exchanger performance in frost conditions via superhydrophobic surface modification
He, H., Zhou, X., Lyu, N., Wang, F., Liang, C., & Zhang, X. (2024) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2024.122914 · Cited by 19 · see citing works
- Authors
- Lin, M., Song, Y., Wu, L., & Ni, L.
- Affiliations
- Harbin Institute of Technology (CN)
- Hisense (China) (CN)
- Corresponding author
- Ni, Long
- ORCID
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2024-05
- Volume
- 244
- Pages
- 122601
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W4391486877
- Cited by
- 24
- References
- 2
- Citations by year
- 2026: 5 · 2025: 9 · 2024: 10
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Applied Thermal Engineering (publishedVersion)
- Funders
- National Natural Science Foundation of China (52278100)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Thermodynamic Systems and Engines
- Keywords
- air-source heat pump, reverse cycle defrosting, vapor injection, flash tank, defrosting time, intermediate heat exchanger, ambient temperature effects
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review