The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Avoiding common errors in X-ray photoelectron spectroscopy data collection and analysis, and properly reporting instrument parameters
Open accessAbstract
Despite numerous tutorials and standards written to the technical community on X-ray photoelectron spectroscopy (XPS), difficulties with data acquisition, analysis, and reporting persist. This work focuses on common errors in XPS that are frequently observed in the scientific literature and their sources. Indeed, this work covers: (i) XPS data collection, initial data analysis, and data presentation, (ii) Handling XPS backgrounds, (iii) Common errors in XPS peak fitting, and (iv) XPS data presentation and reporting. Graphical examples of errors and appropriate ways of handling data and correcting errors are provided. Additional readings are listed for greater in-depth exploration of the subjects discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Biesinger, M. C., Payne, B. P., Grosvenor, A. P., Lau, L. W. M., Gerson, A. R., & Smart, R. S. C. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2010.10.051 · Cited by 11,640
High-Resolution X-Ray Photoemission Spectrum of the Valence Bands of Gold
Shirley, D. A. (1972) · Physical Review B · doi:10.1103/physrevb.5.4709 · Cited by 6,231
Hartree-Slater subshell photoionization cross-sections at 1254 and 1487 eV
Scofield, J. H. (1976) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(76)80015-1 · Cited by 5,981
Seah, M. P., & Dench, W. A. (1979) · Surface and Interface Analysis · doi:10.1002/sia.740010103 · Cited by 5,349
Atomic subshell photoionization cross sections and asymmetry parameters: 1 ⩽ Z ⩽ 103
Yeh, J. J., & Lindau, I. (1985) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(85)90016-6 · Cited by 4,978
Biesinger, M. C., Lau, L. W. M., Gerson, A. R., & Smart, R. S. C. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.07.086 · Cited by 4,592
1,500 scientists lift the lid on reproducibility
Baker, M. (2016) · Nature · doi:10.1038/533452a · Cited by 4,209
Investigation of multiplet splitting of Fe 2p XPS spectra and bonding in iron compounds
Grosvenor, A. P., Kobe, B. A., Biesinger, M. C., & McIntyre, N. S. (2004) · Surface and Interface Analysis · doi:10.1002/sia.1984 · Cited by 3,725
Bro, R., & Smilde, A. K. (2014) · Anal. Methods · doi:10.1039/c3ay41907j · Cited by 3,038
Metadata
- Authors
- Pinder, J. W., Major, G. H., Baer, D. R., Terry, J., Whitten, J. E., Čechal, J., Crossman, J. D., Lizarbe, A. J., Jafari, S., Easton, C. D., Baltrusaitis, J., van Spronsen, M. A., & Linford, M. R.
- Venue
- Applied Surface Science Advances
- Publisher
- Elsevier BV
- Published
- 2024-02
- Volume
- 19
- Pages
- 100534
- ISSN
- 2666-5239 (ISSN-L)
- OpenAlex
- W4390644918
- Cited by
- 263
- References
- 85
- FWCI
- 24.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Avoiding common errors in X-ray photoelectron spectroscopy data collection and analysis, and properly reporting instrument parameters. https://app.cochat.ai/papers/10.1016/j.apsadv.2023.100534
- The paper
- Pinder, J. W., Major, G. H., Baer, D. R., Terry, J., Whitten, J. E., Čechal, J., Crossman, J. D., Lizarbe, A. J., Jafari, S., Easton, C. D., Baltrusaitis, J., van Spronsen, M. A., & Linford, M. R. (2024). Avoiding common errors in X-ray photoelectron spectroscopy data collection and analysis, and properly reporting instrument parameters. Applied Surface Science Advances. https://doi.org/10.1016/j.apsadv.2023.100534
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.