The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enhanced piezoelectric output of the PVDF-TrFE/ZnO flexible piezoelectric nanogenerator by surface modification
Abstract
In this paper, ZnO nano-particles (NPs) were modified by adding a dispersant (n-propylamine, PA) and a silane coupling agent (1H, 2H, 1H, 2H, Perfluorooctyltriethylsilane, PFOES) simultaneously. Further, the PVDF-TrFE/modified ZnO composite films with high crystallinity and large specific surface area were prepared, which acted as the active layer of the piezoelectric nanogenerator (PENG). Four species of films, pure PVDF-TrFE, PVDF-TrFE/ZnO, PVDF-TrFE/ZnO@PA and PVDF-TrFE/ZnO@PA@PFOES were marked P-0-0-0, P-Z-0-0, P-Z-P-0 and P-Z-P-P, respectively. The crystalline phases of the films were determined by Fourier infrared spectroscopy (FT-IR) and wide-angle X-ray diffraction (WXRD). Scanning electron microscope (SEM), Laser scanning confocal microscope (LSCM), Atomic force microscope (AFM) and water contact angle (WCA) measurements were employed to analyze the surface morphology of the films. The thermal properties of the materials were characterized with a differential scanning calorimeter (DSC). From the FTIR spectra and WXRD pattern, it was notable that the modified ZnO NPs promoted the crystallization of β-phase. The results showed that the crystallinity of P-Z-P-P was increased by 36.12% compared to P-0-0-0. Combined with the results of SEM, LSCM and AFM, it can be concluded from WCA that modified ZnO NPs can increase the specific surface area of the film. The piezoelectric strain constant d33 value of P-Z-P-P film was 73.5% higher than that of P-0-0-0 film, and the output voltage value of ITO/P-Z-P-P/Au PENG increased 24.4% than that of ITO/P-0-0-0/Au PENG. After 1000 cycles of testing, the output voltage of the ITO/P-Z-P-P/Au PENG has been maintained at 2.40 V, indicating that the generator exhibited the high mechanical endurance. By clarifying the mechanism of surface modification, it can be concluded that enhanced piezoelectric output of the PENG is contributed to both higher β-phase content and larger charge collecting area by surface modification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, J. S., Shin, K.-Y., Cheong, O. J., Kim, J. H., & Jang, J. (2015) · Scientific Reports · doi:10.1038/srep07887 · Cited by 199
Cited by
Zhou, H., Zhang, Y., Qiu, Y., Wu, H., Qin, W., Liao, Y., Yu, Q., & Cheng, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112569 · Cited by 370
Liu, X., Tong, J., Wang, J., Lu, S., Yang, D., Li, H., Liu, C., & Song, Y. (2023) · Journal of Materials Chemistry C · doi:10.1039/d2tc05291a · Cited by 104
Self-citation
Metadata
- Authors
- Li, J., Zhao, C., Xia, K., Liu, X., Li, D., & Han, J.
- Venue
- Applied Surface Science
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 463
- Pages
- 626-634
- ISSN
- 0169-4332 (ISSN-L)
- OpenAlex
- W2889258016
- Cited by
- 195
- References
- 1
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced piezoelectric output of the PVDF-TrFE/ZnO flexible piezoelectric nanogenerator by surface modification. https://app.cochat.ai/papers/10.1016/j.apsusc.2018.08.266
- The paper
- Li, J., Zhao, C., Xia, K., Liu, X., Li, D., & Han, J. (2019). Enhanced piezoelectric output of the PVDF-TrFE/ZnO flexible piezoelectric nanogenerator by surface modification. Applied Surface Science. https://doi.org/10.1016/j.apsusc.2018.08.266
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.