The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Removal of nickel(II) and lead(II) ions from aqueous solution using peat as a low-cost adsorbent: A kinetic and equilibrium study
Open accessAbstract
Analysis was carried out to determine the physicochemical characteristics – morphological and structural, electrokinetic properties, elemental composition and functional groups – of peat, with a view to its use as a potential adsorbent of heavy metal ions from aqueous solutions. A significant part of the study comprised tests of adsorption of nickel(II) and lead(II) ions from model solutions. It was determined how the parameters of the adsorption process (time, pH, quantity of sorbent) influence the effectiveness of removal of nickel(II) and lead(II) ions. The adsorption kinetics are also described, using a pseudo-first-order model and pseudo-second-order models of types 1–4. The results show strong correspondence to a pseudo-second-order kinetics model of type 1 ( r 2 = 0.999 for all initial concentrations). Another key part of the analysis was the use of the Langmuir and Freundlich models to determine the adsorption isotherms. The experimental data were in strong correspondence with Langmuir’s isotherm model. The sorption capacities of peat with respect to nickel(II) and lead(II) ions were 61.27 mg(Ni 2+ )/g and 82.31 mg(Pb 2+ )/g. Desorption tests confirmed the possibility of reusing peat as an effective sorbent of environmentally harmful metals. A mechanism is also proposed for the adsorption of Ni 2+ and Pb 2+ ions on adsorbent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The adsorption of gases on plane surfaces of glass, mica and platinum
Langmuir, I. (1918) · Journal of the American Chemical Society · doi:10.1021/ja02242a004 · Cited by 23,242
Natural zeolites as effective adsorbents in water and wastewater treatment
Wang, S., & Peng, Y. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.10.029 · Cited by 2,441
Kinetic and adsorptive characterization of biochar in metal ions removal
Kołodyńska, D., Wnętrzak, R., Leahy, J. J., Hayes, M. H. B., Kwapiński, W., & Hubicki, Z. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.05.025 · Cited by 683
Adsorption of Cu(II), Ni(II) and Zn(II) on modified jute fibres
Shukla, S. R., & Pai, R. S. (2005) · Bioresource Technology · doi:10.1016/j.biortech.2004.12.010 · Cited by 287
Cited by
Efficient techniques for the removal of toxic heavy metals from aquatic environment: A review
Carolin, C. F., Kumar, P. S., Saravanan, A., Joshiba, G. J., & Naushad, M. (2017) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2017.05.029 · Cited by 1,687
Water Purification by Using Adsorbents: A Review
Singh, N. B., Nagpal, G., Agrawal, S., & Rachna (2018) · Environmental Technology & Innovation · doi:10.1016/j.eti.2018.05.006 · Cited by 962
Methods to prepare biosorbents and magnetic sorbents for water treatment: a review
Osman, A. I., El-Monaem, E. M. A., Elgarahy, A. M., Aniagor, C. O., Hosny, M., Farghali, M., Rashad, E., Ejimofor, M. I., López-Maldonado, E. A., Ihara, I., et al. (2023) · Environmental Chemistry Letters · doi:10.1007/s10311-023-01603-4 · Cited by 329
Metadata
- Authors
- Bartczak, P., Norman, M., Klapiszewski, Ł., Karwańska, N., Kawalec, M., Baczyńska, M., Wysokowski, M., Zdarta, J., Ciesielczyk, F., & Jesionowski, T.
- Venue
- Arabian Journal of Chemistry
- Publisher
- Scientific Scholar
- Published
- 2018-12
- Volume
- 11
- Issue
- 8
- Pages
- 1209-1222
- ISSN
- 1878-5352 (ISSN-L)
- OpenAlex
- W1270671966
- Cited by
- 184
- References
- 4
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.