Cited by 5Balance, Gait, and Falls PreventionFrailty in Older AdultsNutrition and Health in Aging

Estimating cutpoints of gait speed and sit-to-stand test values for self-reported mobility limitations in a cohort of community-dwelling older adults from Singapore: Comparing receiver operating characteristic (ROC) analysis with adjusted predictive modelling

Open access
Pua, Yong-Hao, Tay, Laura, Terluin, Berend, Clark, Ross Allan, Thumboo, Julian, Tay, Ee-Ling, Mah, Shi-Min, Ng, Yee-Sien·2023·Archives of Gerontology and Geriatrics

Abstract

Objectives Clinical interpretability of the gait speed and 5-times sit-to-stand (5-STS) tests is commonly established by comparing older adults with and without self-reported mobility limitations (SRML) on gait speed and 5-STS performance, and estimating clinical cutpoints for SRML using the receiver operating characteristics (ROC) method. Accumulating evidence, however, suggests that the adjusted predictive modeling (APM) method may be more appropriate to estimate these interpretational cutpoints. Thus, we aimed to compare, in community-dwelling older adults, gait speed and 5-STS cutpoints estimated using the ROC and APM methods.Design Cross-sectional study.Setting and participants This study analyzed data from 955 community-dwelling independently walking older adults (73%women) aged ≥60 years (mean, 68; range, 60-88).Methods Participants completed the 10-metre gait speed and 5-STS tests. Participants were classified as having SRML if they responded "Yes" to either of the 2 questions regarding walking and stair climbing difficulty. Cutpoints for SRML and its component questions were estimated using ROC analysis with Youden criterion and the APM method.Results The proportions of participants with self-reported walking difficulty, self-reported stair climbing difficulty, and SRML were 10%, 19%, and 22%, respectively. Gait speed and 5-STS time were moderately correlated with each other (r=-0.56) and with the self-reported measures (absolute r-values, 0.39-0.44). ROC-based gait speed cutpoints were 0.14 to 0.16 m/s greater than APM-based cutpoints (P < 0.05) whilst ROC-based 5-STS time cutpoints were 0.8 to 3.3 s lower than APM-based cutpoints (P < 0.05 for walking difficulty). Compared with ROC-based cutpoints, APM-based cutptoints were more precise and they varied monotonically with self-reported walking difficulty, self-reported stair climbing difficulty, and SRML.Conclusions and implications In a sample of 955 older adults, our findings of precise and biologically plausible gait speed and 5-STS cutpoints for SRML estimated using the APM method indicate that this promising method could potentially complement or even replace traditional ROC methods.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.archger.2023.105036

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Degraded visual signals can significantly disrupt sensorimotor integration.

    “Previous electroencephalography (EEG) studies have established that degraded visual signals can significantly disrupt sensorimotor integration and impair walking ability.[3–5]”

    From Brain Rewires to Stabilize Walking During Visual Impairment · cites this paper as [4]

    The Introduction and Discussion address gait-speed and sit-to-stand cutpoints for self-reported mobility limitations, not the effects of degraded visual signals. Searches for visual signals, EEG, and sensorimotor integration found no passage addressing the attributed claim. Page numbers were not available in our copy. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • Degraded visual signals can impair walking ability.

    “Previous electroencephalography (EEG) studies have established that degraded visual signals can significantly disrupt sensorimotor integration and impair walking ability.[3–5]”

    From Brain Rewires to Stabilize Walking During Visual Impairment · cites this paper as [4]

    The Methods (§2.2) measure self-reported walking and stair-climbing difficulty, and the Discussion (§4) addresses physical demands and gait-speed cutpoints. Searches for degraded visual signals, visual impairment, sensorimotor integration, and EEG found no passage connecting visual signals to walking ability in our copy. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 33 · Cited by 5

Authors
Pua, Y.-H., Tay, L., Terluin, B., Clark, R. A., Thumboo, J., Tay, E.-L., Mah, S.-M., & Ng, Y.-S.
Affiliations
  • SingHealth (SG)
  • Sengkang General Hospital (SG)
  • Amsterdam Public Health (NL)
  • University of the Sunshine Coast (AU)
  • Singapore General Hospital (SG)
Corresponding author
Pua, Yong-Hao
Venue
Archives of Gerontology and Geriatrics
Publisher
Elsevier BV
Published
2023-09
Volume
112
Pages
105036
ISSN
0167-4943 (ISSN-L)
OpenAlex
W4365518115
Cited by
5
References
33
Citations by year
2026: 3 · 2025: 1 · 2024: 1
FWCI
3.08
Type
journal article
Language
en
Open access
Locations
  • Archives of Gerontology and Geriatrics (publishedVersion)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (submittedVersion, other-oa)
  • Amsterdam UMC (VU Amsterdam) - Institutional Repository (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Funders
  • Medical Research Council
  • National Medical Research Council (CGAug16M011, CGAug16C027)
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Health Sciences › Medicine › Geriatrics and Gerontology › Frailty in Older Adults
  • Health Sciences › Medicine › Physiology › Nutrition and Health in Aging
Keywords
walking speed, sit-to-stand test, receiver operating characteristic, community-dwelling older adults, walking difficulty, functional mobility assessment
MeSH terms
Walking Speed, Aged, Cross-Sectional Studies, Female, Gait, Humans, ROC Curve, Singapore, Geriatric Assessment, Walking, Mobility Limitation, Independent Living, Self Report

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review