Head-to-Head Comparison of Kinematic Alignment Versus Mechanical Alignment for Total Knee Arthroplasty
Abstract
Background Seeing as there are many alignment strategies for total knee arthroplasty (TKA), we need to determine differences between them in a rigorous scientific way. Therefore, we sought to compare perioperative and postoperative functional outcomes in patients undergoing TKA for varus osteoarthritis with a mechanical alignment target vs a kinematic alignment target, both executed with the same implant and same technological guidance. Methods One hundred consecutive patients who underwent TKA using a mechanical alignment technique were 1:1 matched to 100 patients who underwent TKA using a kinematic alignment (KA) technique, using the same implant and robotic technology. Patient-reported outcomes were measured postoperatively at 1 and 2 years. Power analysis revealed 94 patients to detect a significant difference. Results Mean Visual Analog Scale scores were higher in the mechanical alignment group during the first 6 weeks (P = .04), but statistically similar at 1 year. Six-week Veterans RAND 12 Item Health Survey mental and physical components were statistically similar (P = .1). Patients did not differ in 6-week or 1-year knee range of motion (P > .43). Knee Injury and Osteoarthritis Outcome Score Joint Replacement was significantly better in the KA group at 6 weeks, 1 year, and 2 years (P = .09). Forgotten Joint Score at 1 and 2 years postoperatively were significantly higher in the KA group (P Conclusion Patients undergoing TKA with KA experienced less pain in 6 weeks af…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Personalized approaches have been reported to achieve improved balance, kinematics, and outcomes compared to mechanical alignment.
“These personalized approaches have been reported to achieve improved balance, kinematics, and outcomes compared to mechanical alignment [8, 9].”
From Imageless robotic total knee arthroplasty determines similar coronal plane alignment of the knee (CPAK) parameters to long leg radiographs (2024) · cites this paper as [9]
Personalized alignment strategies that target recreation of native knee joint morphology may limit the need for soft tissue releases and result in more natural kinematics.
“Personalized alignment strategies that target recreation of native knee joint morphology may limit the need for soft tissue releases and result in more natural kinematics [8, 9, 34, 35].”
From Imageless robotic total knee arthroplasty determines similar coronal plane alignment of the knee (CPAK) parameters to long leg radiographs (2024) · cites this paper as [9]
Cited by
Sorted by citations
Edelstein, A. I., Orsi, A. D., Plaskos, C., Coffey, S., & Suleiman, L. I. (2024) · Arthroplasty · doi:10.1186/s42836-024-00231-9 · Cited by 11 · see citing works
“These personalized approaches have been reported to achieve improved balance, kinematics, and outcomes compared to mechanical alignment [8, 9].”
Background
- Authors
- Elbuluk, A. M., Jerabek, S. A., Suhardi, V. J., Sculco, P. K., Ast, M. P., & Vigdorchik, J. M.
- Affiliations
- Hospital for Special Surgery (US)
- Corresponding author
- Vigdorchik, Jonathan M.
- ORCID
- Venue
- The Journal of Arthroplasty
- Publisher
- Elsevier BV
- Published
- 2022-08
- Volume
- 37
- Issue
- 8
- Pages
- S849-S851
- ISSN
- 0883-5403 (ISSN-L)
- OpenAlex
- W4210539047
- Cited by
- 113
- References
- 0
- Citations by year
- 2026: 33 · 2025: 34 · 2024: 26 · 2023: 12 · 2022: 8
- FWCI
- 19.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- The Journal of Arthroplasty (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- total knee arthroplasty, kinematic alignment, mechanical alignment, varus knee osteoarthritis, robotic surgery, postoperative pain, Forgotten Joint Score, patient-reported outcomes, knee range of motion, KOOS
- MeSH terms
- Biomechanical Phenomena, Humans, Knee Joint, Knee Prosthesis, Range of Motion, Articular, Arthroplasty, Replacement, Knee, Osteoarthritis, Knee
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review