Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 283

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

The effect of oblique femoral tunnel placement on rotational constraint of the knee reconstructed using patellar tendon autografts

Scopp, Jason M, Jasper, Louis E, Belkoff, Stephen M, Moorman, Claude T·2004·Arthroscopy: The Journal of Arthroscopic & Related Surgery

Abstract

PURPOSE: Despite the high long-term success rates of anterior cruciate ligament (ACL) reconstructions, 8% of patients undergoing this primary procedure have recurrent disability and graft failure. Nonanatomic tunnel positioning (primarily of the femoral tunnel) accounts for most of all technical failures. We hypothesized that reconstructions that closely recreate the oblique femoral attachment of the ACL would result in more normal knee rotational stability than more vertical reconstruction. The purpose of this study was to determine whether obliquity of the femoral tunnel in the coronal (frontal) plane has an effect on rotational constraint after ACL reconstruction, as measured by anterior tibial translation, external rotation, and internal rotation. TYPE OF STUDY: Ex vivo biomechanical study. METHODS: Ten matched pairs of fresh-frozen cadaver knees were alternately assigned to a standard or an oblique tunnel position reconstruction. Each knee was tested at 30 degrees and 90 degrees of flexion on a materials testing machine in ACL-intact, ACL-sectioned, and ACL-reconstructed states. A 100-N load was applied at a rate of 10 N/second, and anterior tibial translation was measured. Then 6.5 Nm of torque were applied, and external tibial rotation and internal tibial rotation were measured. The effects of tunnel placement and ligament condition were analyzed with a repeated measures analysis of variance. Significance was set at P < or =.05 (Tukey's test). RESULTS: At 30 degrees of flexion, internal tibial rotation in oblique reconstruction was restored to intact values and was significantly less than the internal tibial rotation values in standard reconstruction. Internal tibial rotation in standard reconstruction was significantly greater than intact values. No significant differences were found between standard and oblique tunnel reconstructions and the respective intact values for the remaining internal tibial rotation and all external tibial rotation tests, regardless of flexion angle. CONCLUSIONS: In our biomechanical model, ACL reconstructions using oblique femoral tunnels restored normal knee kinematics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.arthro.2004.01.001

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 283

Metadata

Authors
Scopp, J. M., Jasper, L. E., Belkoff, S. M., & Moorman, C. T.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2004-03
Volume
20
Issue
3
Pages
294-299
ISSN
0749-8063 (ISSN-L)
OpenAlex
W2085703711
Cited by
283
References
14
FWCI
6.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of oblique femoral tunnel placement on rotational constraint of the knee reconstructed using patellar tendon autografts. https://app.cochat.ai/papers/10.1016/j.arthro.2004.01.001
The paper
Scopp, J. M., Jasper, L. E., Belkoff, S. M., & Moorman, C. T. (2004). The effect of oblique femoral tunnel placement on rotational constraint of the knee reconstructed using patellar tendon autografts. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/j.arthro.2004.01.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.