The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Prospective Randomized Clinical Trial of Single- Versus Double-Row Suture Anchor Repair in 2- to 4-cm Rotator Cuff Tears: Clinical and Magnetic Resonance Imaging Results
Abstract
PURPOSE: The purpose of this study was to compare the clinical outcomes and the retear rates of arthroscopic single-row (SR) and double-row (DR) suture anchor repair in 2- to 4-cm rotator cuff tears. METHODS: From 2005 to 2007, 71 patients with a 2- to 4-cm rotator cuff tear (proven by arthroscopy) were prospectively randomized to SR and DR repair groups. Of these patients, 62 (31 in each group) were available for evaluation at final follow-up. Demographic data, clinical scores, mean surgical times, and patient satisfaction were compared. Retear rates and clinical scores were also analyzed for 47 patients who underwent follow-up magnetic resonance imaging. RESULTS: Comparisons of demographic data, tear size on preoperative magnetic resonance imaging, global fatty degeneration index, and concomitant procedures showed no differences between the SR and DR groups. Preoperative clinical scores were significantly improved postoperatively in both groups. No intergroup differences in pain visual analog scale, American Shoulder and Elbow Surgeons, Constant, or University of California, Los Angeles scores were found at final follow-up. Only mean surgical time was significantly different between the 2 groups. In the SR group, there were 4 full-thickness retears and 11 partial-thickness retears, whereas in the DR group, there were 6 full-thickness retears and 1 partial-thickness retear. However, despite numerical differences, these differences were not statistically different. Statistically, there were no significant differences both in full-thickness retear (P = .999) and retear including partial-thickness tear between the 2 groups (P = .124). CONCLUSIONS: This study indicates that the clinical results and retear rates of DR repair with 1 additional medial suture anchor were not significantly different from those of SR repairs with 2 lateral suture anchors in patients with medium to large rotator cuff tear. LEVEL OF EVIDENCE: Level I, randomized controlled trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No adjustments are needed for multiple comparisons.
Rothman, K. J. (1990) · Epidemiology · doi:10.1097/00001648-199001000-00010 · Cited by 5,965
Cited by
McElvany, M. D., McGoldrick, E., Gee, A. O., Neradilek, M. B., & Matsen, F. A. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546514529644 · Cited by 485
Hein, J., Reilly, J. M., Chae, J., Maerz, T., & Anderson, K. (2015) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2015.06.004 · Cited by 284
Millett, P. J., Warth, R. J., Dornan, G. J., Lee, J. T., & Spiegl, U. J. (2014) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2013.10.006 · Cited by 281
Metadata
- Authors
- Koh, K. H., Kang, K. C., Lim, T. K., Shon, M. S., & Yoo, J. C.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2011-04
- Volume
- 27
- Issue
- 4
- Pages
- 453-462
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2012970839
- Cited by
- 189
- References
- 1
- FWCI
- 18.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.