Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 189

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Prospective Randomized Clinical Trial of Single- Versus Double-Row Suture Anchor Repair in 2- to 4-cm Rotator Cuff Tears: Clinical and Magnetic Resonance Imaging Results

Koh, Kyoung Hwan, Kang, Kyung Chung, Lim, Tae Kang, Shon, Min Soo, Yoo, Jae Chul · 2011 · Arthroscopy: The Journal of Arthroscopic & Related Surgery

Abstract

PURPOSE: The purpose of this study was to compare the clinical outcomes and the retear rates of arthroscopic single-row (SR) and double-row (DR) suture anchor repair in 2- to 4-cm rotator cuff tears. METHODS: From 2005 to 2007, 71 patients with a 2- to 4-cm rotator cuff tear (proven by arthroscopy) were prospectively randomized to SR and DR repair groups. Of these patients, 62 (31 in each group) were available for evaluation at final follow-up. Demographic data, clinical scores, mean surgical times, and patient satisfaction were compared. Retear rates and clinical scores were also analyzed for 47 patients who underwent follow-up magnetic resonance imaging. RESULTS: Comparisons of demographic data, tear size on preoperative magnetic resonance imaging, global fatty degeneration index, and concomitant procedures showed no differences between the SR and DR groups. Preoperative clinical scores were significantly improved postoperatively in both groups. No intergroup differences in pain visual analog scale, American Shoulder and Elbow Surgeons, Constant, or University of California, Los Angeles scores were found at final follow-up. Only mean surgical time was significantly different between the 2 groups. In the SR group, there were 4 full-thickness retears and 11 partial-thickness retears, whereas in the DR group, there were 6 full-thickness retears and 1 partial-thickness retear. However, despite numerical differences, these differences were not statistically different. Statistically, there were no significant differences both in full-thickness retear (P = .999) and retear including partial-thickness tear between the 2 groups (P = .124). CONCLUSIONS: This study indicates that the clinical results and retear rates of DR repair with 1 additional medial suture anchor were not significantly different from those of SR repairs with 2 lateral suture anchors in patients with medium to large rotator cuff tear. LEVEL OF EVIDENCE: Level I, randomized controlled trial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.arthro.2010.11.059

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 189

Metadata

Authors
Koh, K. H., Kang, K. C., Lim, T. K., Shon, M. S., & Yoo, J. C.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2011-04
Volume
27
Issue
4
Pages
453-462
ISSN
0749-8063 (ISSN-L)
OpenAlex
W2012970839
Cited by
189
References
1
FWCI
18.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.