Long-Term Outcome of Arthroscopic Massive Rotator Cuff Repair: The Importance of Double-Row Fixation
Open accessAbstract
PURPOSE: The purpose of this study was to (1) evaluate the long-term functional outcome of arthroscopic rotator cuff repair of massive rotator cuff tears (RCTs) and (2) compare double-row (DR) and single-row (SR) repairs. METHODS: This was a retrospective review of massive RCTs treated with an arthroscopic rotator cuff repair over an 8-year period. Minimum 5-year follow-up was available for 126 repairs at a mean of 99 months. Among 107 complete repairs, there were 62 SR and 45 DR repairs. Functional outcome was determined by University of California, Los Angeles (UCLA) and American Shoulder and Elbow Surgeons scores. A multivariate analysis was performed to examine the role of a DR repair. RESULTS: For all repairs combined, improvements were observed in forward flexion (132° v 168°), pain (6.3 v 1.3), UCLA score (15.7 v 30.7), and American Shoulder and Elbow Surgeons score (41.7 v 85.7) (P < .001). A good or excellent outcome, obtained in 78% of cases, was associated with a complete repair (P = .035) and a DR repair (P = .008). When we excluded partial repairs, postoperative UCLA gain was greater after a DR repair (P = .007). Patients reported their shoulder as feeling closer to normal after a DR repair compared with an SR repair (93.5% v 84.4%, P = .006). A DR repair was 4.9 times more likely to lead to a good or excellent outcome (P = .021). CONCLUSIONS: When a DR repair of a massive RCT is possible, on the basis of the ability to mobilize the tendons, a better long-term functional outcome can be expected compared with an SR repair. Given the known high risk of recurrence after repair of massive RCTs and the knowledge that functional outcome is related to recurrence, a DR repair of massive RCTs should be performed when there is sufficient tendon mobility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scoring Systems for the Functional Assessment of the Shoulder
Kirkley, A., Griffin, S., & Dainty, K. (2003) · Arthroscopy · doi:10.1016/j.arthro.2003.10.030 · Cited by 504
Cited by
Millett, P. J., Warth, R. J., Dornan, G. J., Lee, J. T., & Spiegl, U. J. (2014) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2013.10.006 · Cited by 281
Metadata
- Authors
- Denard, P. J., Jiwani, A. Z., Lädermann, A., & Burkhart, S. S.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 28
- Issue
- 7
- Pages
- 909-915
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2152412959
- Cited by
- 165
- References
- 1
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-Term Outcome of Arthroscopic Massive Rotator Cuff Repair: The Importance of Double-Row Fixation. https://app.cochat.ai/papers/10.1016/j.arthro.2011.12.007
- The paper
- Denard, P. J., Jiwani, A. Z., Lädermann, A., & Burkhart, S. S. (2012). Long-Term Outcome of Arthroscopic Massive Rotator Cuff Repair: The Importance of Double-Row Fixation. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/j.arthro.2011.12.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.