Biomechanical Evaluation of Capsulotomy, Capsulectomy, and Capsular Repair on Hip Rotation
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the effect of different types of capsulotomies on hip rotational biomechanical characteristics. METHODS: Seven fresh-frozen cadaveric hip specimens were thawed and dissected, leaving the hip capsule and labrum intact. The femur was transected and potted, and each specimen was placed in a custom loading apparatus that allowed for adjustment of flexion, extension, and axial rotation of the femur. Six reflective infrared markers were attached to the specimens to track the motion of the femoral head with respect to the acetabulum in real time, and external rotation was produced by applying a torque of 10 Nm to the hip specimens. Data analysis was performed using the 3-dimensional position of the markers in space. The specimens were tested in neutral flexion and 40° of flexion in the following capsular states: intact, interportal capsulotomy, T-capsulotomy, repaired capsulotomy, and capsulectomy. Paired t tests and analysis of variance were used with an α value of .05 set as significant. RESULTS: With the hip in neutral flexion, there was increased external rotation with a T-capsulotomy (91.1° ± 20.3°, P = .029) and capsulectomy (91.9° ± 19.6°, P = .015) compared with the intact hip (83.2° ± 20.5°). After complete repair of the T-capsulotomy (87.4° ± 20.6°), there was no significant difference in external rotation compared with the intact hip. No significant differences were seen between groups at 40° of hip flexion. CONCLUSIONS: A T-capsulotomy showed significantly increased external rotation versus the intact and interportal capsulotomy states. The repaired T-capsulotomy restored the rotational profile back to the native state. CLINICAL RELEVANCE: Many methods of capsular treatment during hip arthroscopy exist. Capsulotomy and capsulectomy do not restore the external rotation restraint of the hip back to its native state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myers, C. A., Register, B. C., Lertwanich, P., Ejnisman, L., Pennington, W. W., Giphart, J. E., LaPrade, R. F., & Philippon, M. J. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546511412161 · Cited by 360
Domb, B. G., Philippon, M. J., & Giordano, B. D. (2013) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2012.04.057 · Cited by 331
The Function of the Hip Capsular Ligaments: A Quantitative Report
Martin, H. D., Savage, A., Braly, B. A., Palmer, I. J., Beall, D. P., & Kelly, B. (2008) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2007.08.024 · Cited by 323
Self-citationAcute Iatrogenic Dislocation Following Hip Impingement Arthroscopic Surgery
Matsuda, D. K. (2009) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2008.12.011 · Cited by 313
Mei-Dan, O., McConkey, M. O., & Brick, M. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.12.005 · Cited by 219
Ranawat, A. S., McClincy, M., & Sekiya, J. K. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01367 · Cited by 208
The mechanical properties of the human hip capsule ligaments
Hewitt, J. D., Glisson, R. R., Guilak, F., & Vail, T. P. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.27674 · Cited by 207
Regional material properties of the human hip joint capsule ligaments
Hewitt, J., Guilak, F., Glisson, R. R., & Vail, T. P. (2001) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(00)00035-8 · Cited by 196
Capsular Management During Hip Arthroscopy: From Femoroacetabular Impingement to Instability
Bedi, A., Galano, G., Walsh, C., & Kelly, B. T. (2011) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.08.288 · Cited by 192
Self-citationRoutine Complete Capsular Closure During Hip Arthroscopy
Harris, J. D., Slikker, W., Gupta, A. K., McCormick, F. M., & Nho, S. J. (2013) · Arthroscopy Techniques · doi:10.1016/j.eats.2012.11.007 · Cited by 184
Self-citation
Cited by
Does Capsular Laxity Lead to Microinstability of the Native Hip?
Han, S., Alexander, J. W., Thomas, V. S., Choi, J., Harris, J. D., Doherty, D. B., Jeffers, J. R. T., & Noble, P. C. (2018) · The American Journal of Sports Medicine · doi:10.1177/0363546518755717 · Cited by 90
Metadata
- Authors
- Abrams, G. D., Hart, M. A., Takami, K., Bayne, C. O., Kelly, B. T., Espinoza Orías, A. A., & Nho, S. J.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2015-08
- Volume
- 31
- Issue
- 8
- Pages
- 1511-1517
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2090453011
- Cited by
- 191
- References
- 17
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomechanical Evaluation of Capsulotomy, Capsulectomy, and Capsular Repair on Hip Rotation. https://app.cochat.ai/papers/10.1016/j.arthro.2015.02.031
- The paper
- Abrams, G. D., Hart, M. A., Takami, K., Bayne, C. O., Kelly, B. T., Espinoza Orías, A. A., & Nho, S. J. (2015). Biomechanical Evaluation of Capsulotomy, Capsulectomy, and Capsular Repair on Hip Rotation. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/j.arthro.2015.02.031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.