Electrocardiogram soft computing using hybrid deep learning CNN-ELM
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Abstract Electrocardiogram (ECG) can reflect the state of human heart and is widely used in clinical cardiac examination. However, the electrocardiogram signal is very weak, the anti-interference ability is poor, easy to be affected by the noise. Doctors face difficulties in diagnosing arrhythmias. Therefore, automatic recognition and classification of ECG signals is an important and indispensable task. Since the beginning of the 21 st century, deep learning has developed rapidly and has shown the most advanced performance in various fields. This paper presents a method of combining (Convolutional neural network) CNN and ELM (extreme learning machine). The accuracy rate is 97.50%. Compared with the state-of-the-art methods, this method improves the accuracy of ECG automatic classification and has good generalization ability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Cited by
Classifying Cardiac Arrhythmia from ECG Signal Using 1D CNN Deep Learning Model
Ahmed, A. A., Ali, W., Abdullah, T. A. A., & Malebary, S. J. (2023) · Mathematics · doi:10.3390/math11030562 · Cited by 193
“Furthermore Furthermore, several recent studies have been proposed to classify cardiac arrhythmias using deep learning techniques such as convolutional neural networks (CNNs) [5,21,22].”
BackgroundIslam, M. R., Kabir, M. M., Mridha, M. F., Alfarhood, S., Safran, M., & Che, D. (2023) · Sensors · doi:10.3390/s23115204 · Cited by 185
“…CNN Acc = 0.913 F1_score = 0.851 Chen et al. [40] 2020 CNN+LSTM Acc = 0.992 F1_score = 0.908 Yao et al. [46] 2020 ATI-CNN Acc = 0.812 Zhou and Tan [47] 2020 CNN Acc = 0.975 Hammad et al. [43] 2020 DNN + GA + KNN Acc = 0.980 F1_score = 0.959 Kim et al. [44] 2022 ResNet + biLSTM Acc = 0.992…”
InfluentialReinforcement Learning with an Ensemble of Binary Action Deep Q-Networks
M. Hafiz, A., Hassaballah, M., Alqahtani, A., Alsubai, S., & Abdel Hameed, M. (2023) · Computer Systems Science and Engineering · doi:10.32604/csse.2023.031720 · Cited by 33
Metadata
- Authors
- Zhou, S., & Tan, B.
- Venue
- Applied Soft Computing
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 86
- Pages
- 105778
- ISSN
- 1568-4946 (ISSN-L)
- OpenAlex
- W2977638463
- Cited by
- 193
- References
- 2
- FWCI
- 20.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.