Right-Sided Univentricular Cardiac Assistance in a Failing Fontan Circulation
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977 · cited 1×
“Mechanical assist devices have proven an ability to maintain candidates in life during the waiting time and to promote recovery of hemodynamically strained organs [1].”
BackgroundBasal Pulmonary Vascular Resistance and Nitric Oxide Responsiveness Late After Fontan-Type Operation
Khambadkone, S., Li, J., de Leval, M. R., Cullen, S., Deanfield, J. E., & Redington, A. N. (2003) · Circulation · doi:10.1161/01.cir.0000074210.49434.40 · Cited by 222
Cited by
Rychik, J., Atz, A. M., Celermajer, D. S., Deal, B. J., Gatzoulis, M. A., Gewillig, M. H., Hsia, T.-Y., Hsu, D. T., Kovacs, A. H., McCrindle, B. W., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000696 · Cited by 1,011
2019 EACTS Expert Consensus on long-term mechanical circulatory support
Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz098 · Cited by 399
Kirk, R., Dipchand, A. I., Rosenthal, D. N., Addonizio, L., Burch, M., Chrisant, M., Dubin, A., Everitt, M., Gajarski, R., Mertens, L., et al. (2014) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2014.06.002 · Cited by 340
Failure of the Fontan Circulation
Gewillig, M., & Goldberg, D. J. (2014) · Heart Failure Clinics · doi:10.1016/j.hfc.2013.09.010 · Cited by 209
“In this setting the interposition of a subpulmonary assist device is required, and this has been reported in one instance as a bridge to transplantation.(44) In a second case, a total artificial heart was used to bridge a patient with a failing Fontan circulation to transplantation.”
BackgroundA Hybrid Experimental-Computational Modeling Framework for Cardiovascular Device Testing
Kung, E., Farahmand, M., & Gupta, A. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4042665 · Cited by 28
Metadata
- Authors
- Prêtre, R., Häussler, A., Bettex, D., & Genoni, M.
- Venue
- The Annals of Thoracic Surgery
- Publisher
- Elsevier BV
- Published
- 2008-09
- Volume
- 86
- Issue
- 3
- Pages
- 1018-1020
- ISSN
- 0003-4975 (ISSN-L)
- OpenAlex
- W2137886815
- Cited by
- 159
- References
- 2
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.