Intraoperative Near-Infrared Imaging Can Identify Pulmonary Nodules
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background Over 80,000 people undergo pulmonary resection for a lung nodule in the United States each year. Small nodules are frequently missed or difficult to find despite preoperative imaging. We hypothesized that near-infrared (NIR) imaging technology could be used to identify and locate lung nodules during surgery. Methods We enrolled 18 patients who were diagnosed with a pulmonary nodule that required resection. All patients had a fine-cut 1mm computed tomography scan preoperatively. The patients were given systemic 5 mg/kg indocyanine green (ICG) and then underwent an open thoracotomy 24 hours later. NIR imaging was used to identify the primary nodule and search for additional nodules that were not found by visual inspection or manual palpation of the ipsilateral lung. Results Manual palpation and visual inspection identified all 18 primary pulmonary nodules and no additional lesions. Intraoperative NIR imaging detected 16 out of the 18 primary nodules. NIR imaging also identified 5 additional subcentimeter nodules: 3 metastatic adenocarcinomas and 2 metastatic sarcomas. This technology could identify nodules as small as 0.2 cm and as deep as 1.3 cm from the pleural surface. This approach discovered 3 nodules that were in different lobes than the primary tumor. Nodule fluorescence was independent of size, metabolic activity, histology, tumor grade and vascularity. Conclusions This is the first-in-human demonstration of identifying pulmonary nodules during Thoracic surgery with NIR imaging without a priori knowledge of their location or existence. NIR imaging can detect pulmonary nodules during lung resections that are poorly visualized on computed tomography and difficult to discriminate on finger palpation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matsumura, Y., & Maeda, H. (1986) · PubMed · Cited by 6,781
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
Translation of Near-Infrared Fluorescence Imaging Technologies: Emerging Clinical Applications
Sevick-Muraca, E. M. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-070910-083323 · Cited by 339 · cited 1×
“NIR imaging depends on a scanning device and an intravenous contrast agent (21).”
BackgroundNear‐infrared fluorescence‐guided resection of colorectal liver metastases
van der Vorst, J. R., Schaafsma, B. E., Hutteman, M., Verbeek, F. P. R., Liefers, G., Hartgrink, H. H., Smit, V. T. H. B. M., Löwik, C. W. G. M., van de Velde, C. J. H., Frangioni, J. V., et al. (2013) · Cancer · doi:10.1002/cncr.28203 · Cited by 309
Binding properties of indocyanine green in human blood.
Yoneya, S., Saito, T., Komatsu, Y., Koyama, I., Takahashi, K., & Duvoll-Young, J. (1998) · PubMed · Cited by 246
Nanotechnology Applications in Surgical Oncology
Singhal, S., Nie, S., & Wang, M. D. (2010) · Annual Review of Medicine · doi:10.1146/annurev.med.60.052907.094936 · Cited by 190 · cited 1×
“Based on preclinical data (12, 13) on the enhanced permeability and retention effect (EPR) in lung tissue, we hypothesized that pulmonary nodules could be identified by giving systemic ICG 24 hours prior to surgery.”
BackgroundSelf-citationPredina, J., Eruslanov, E., Judy, B., Kapoor, V., Cheng, G., Wang, L.-C., Sun, J., Moon, E. K., Fridlender, Z. G., Albelda, S., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211850110 · Cited by 188 · cited 1×
“Frozen tumor sections were prepared as previously described (15).”
MethodSelf-citationHeneweer, C., Holland, J. P., Divilov, V., Carlin, S., & Lewis, J. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.083998 · Cited by 184 · cited 1×
“Once in the tumor microenvironment, these particles are retained due to global properties such as molecular size, shape, charge and polarity, rather than tumorspecific targeting mechanisms such as ligand-receptor interactions (24).”
BackgroundPowell, T. I., Jangra, D., Clifton, J. C., Lara-Guerra, H., Church, N. G., English, J. C., Evans, K. G., Yee, J., Coxson, H. O., Mayo, J. R., et al. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000137132.01881.57 · Cited by 156
Madajewski, B., Judy, B. F., Mouchli, A., Kapoor, V., Holt, D. E., Wang, M. D., Nie, S., & Singhal, S. K. (2012) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-12-1188 · Cited by 117 · cited 6×
“The NIR agent, dose and time point were selected based on extensive preclinical studies from our laboratory (12).”
BackgroundSelf-citation
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Self-citationLiu, J., Chen, C., Ji, S., Liu, Q., Ding, D., Zhao, D., & Liu, B. (2017) · Chemical Science · doi:10.1039/c6sc04384d · Cited by 186
Metadata
- Authors
- Okusanya, O. T., Holt, D., Heitjan, D., Deshpande, C., Venegas, O., Jiang, J., Judy, R., DeJesus, E., Madajewski, B., Oh, K., Wang, M., Albelda, S. M., Nie, S., & Singhal, S.
- Venue
- The Annals of Thoracic Surgery
- Publisher
- Elsevier BV
- Published
- 2014-10
- Volume
- 98
- Issue
- 4
- Pages
- 1223-1230
- ISSN
- 0003-4975 (ISSN-L)
- OpenAlex
- W2122382231
- Cited by
- 180
- References
- 14
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.