CoChat

Novel Percutaneous Tracheostomy for Critically Ill Patients With COVID-19

Open access
Angel, Luis, Kon, Zachary N., Chang, Stephanie H., Rafeq, Samaan, Palasamudram Shekar, Saketh, Mitzman, Brian, Amoroso, Nancy, Goldenberg, Ronald, Sureau, Kimberly, Smith, Deane E., Cerfolio, Robert J. · 2020 · The Annals of Thoracic Surgery
Cited by 168

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background Coronavirus 2019 (COVID-19) is a worldwide pandemic, with many patients requiring prolonged mechanical ventilation. Tracheostomy is not recommended by current guidelines as it is considered a superspreading event owing to aerosolization that unduly risks health care workers. Methods Patients with severe COVID-19 who were on mechanical ventilation for 5 days or longer were evaluated for percutaneous dilational tracheostomy. We developed a novel percutaneous tracheostomy technique that placed the bronchoscope alongside the endotracheal tube, not inside it. That improved visualization during the procedure and continued standard mechanical ventilation after positioning the inflated endotracheal tube cuff in the distal trachea. This technique offers a significant mitigation for the risk of virus aerosolization during the procedure. Results From March 10 to April 15, 2020, 270 patients with COVID-19 required invasive mechanical ventilation at New York University Langone Health Manhattan’s campus; of those, 98 patients underwent percutaneous dilational tracheostomy. The mean time from intubation to the procedure was 10.6 ± 5 days. Currently, 32 patients (33%) do not require mechanical ventilatory support, 19 (19%) have their tracheostomy tube downsized, and 8 (8%) were decannulated. Forty patients (41%) remain on full ventilator support, and 19 (19%) are weaning from mechanical ventilation. Seven patients (7%) died as a result of respiratory and multiorgan failure. Tracheostomy-related bleeding was the most common complication (5 patients). None of health care providers has had symptoms or tested positive for COVID-19. Conclusions Our percutaneous tracheostomy technique appears to be safe and effective for COVID-19 patients and safe for health care workers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.athoracsur.2020.04.010

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Angel, L., Kon, Z. N., Chang, S. H., Rafeq, S., Palasamudram Shekar, S., Mitzman, B., Amoroso, N., Goldenberg, R., Sureau, K., Smith, D. E., & Cerfolio, R. J.
Venue
The Annals of Thoracic Surgery
Publisher
Elsevier BV
Published
2020-09
Volume
110
Issue
3
Pages
1006-1011
ISSN
0003-4975 (ISSN-L)
OpenAlex
W3020673234
Cited by
168
References
3
FWCI
19.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.