To improve our understanding of indoor and outdoor personal exposures to common environmental toxicants released into the environment, new technologies that can monitor and quantify the toxicants anytime anywhere are needed. This paper presents a wearable sensor to provide such capabilities. The sensor can communicate with a common smart phone and provides accurate measurement of volatile organic compound concentration at a personal level in real time, providing environmental toxicants data every three minutes. The sensor has high specificity and sensitivity to aromatic, alkyl, and chlorinated hydrocarbons with a resolution as low as 4 parts per billion (ppb), with a detection range of 4 ppb to 1000 ppm (parts per million). The sensor's performance was validated using Gas Chromatography and Selected Ion Flow Tube - Mass Spectrometry reference methods in a variety of environments and activities with overall accuracy higher than 81% (r2 > 0.9). Field tests examined personal exposure in various scenarios including: indoor and outdoor environments, traffic exposure in different cities which vary from 0 to 50 ppmC (part-per-million carbon from hydrocarbons), and pollutants near the 2010 Deepwater Horizon's oil spill. These field tests not only validated the performance but also demonstrated unprecedented high temporal and spatial toxicant information provided by the new technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pasluosta, C. F., Gassner, H., Winkler, J., Klucken, J., & Eskofier, B. M. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2461555 · Cited by 323
“sensors technologies [38].”
Shameer, K., Badgeley, M. A., Miotto, R., Glicksberg, B. S., Morgan, J. W., & Dudley, J. T. (2017) · Briefings in Bioinformatics · doi:10.1093/bib/bbv118 · Cited by 198
“Additional devices track patients’ ambient environmental conditions to assess their local environment for air quality, light [86], climatic variations, ozone [87] and volatile organic compounds [88–90].”
BackgroundA review of optical interferometry techniques for VOC detection
Khan, S., Le Calvé, S., & Newport, D. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.111782 · Cited by 106
“surface acoustic wave [27], quartz crystal microbalances [28], and tuning fork [29], gravimetric-based gas sensors [30], metal-oxide semiconductor (MOS) gas sensors [31] and optical sensor such as colorimetric gas sensors [32], non-dispersive infrared gas sensors[29] and UV spectrophotometry gas sensors [33].”
Background
Metadata
- Authors
- Chen, C., Driggs Campbell, K., Negi, I., Iglesias, R. A., Owens, P., Tao, N., Tsow, F., & Forzani, E. S.
- Venue
- Atmospheric Environment
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 54
- Pages
- 679-687
- ISSN
- 1352-2310 (ISSN-L)
- OpenAlex
- W1979564258
- Cited by
- 57
- References
- 0
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new sensor for the assessment of personal exposure to volatile organic compounds. https://app.cochat.ai/papers/10.1016/j.atmosenv.2012.01.048
- The paper
- Chen, C., Driggs Campbell, K., Negi, I., Iglesias, R. A., Owens, P., Tao, N., Tsow, F., & Forzani, E. S. (2012). A new sensor for the assessment of personal exposure to volatile organic compounds. Atmospheric Environment. https://doi.org/10.1016/j.atmosenv.2012.01.048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.