Identification of a modified Wiener–Hammerstein system and its application in electrically stimulated paralyzed skeletal muscle modeling
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electrical muscle stimulation demonstrates potential for restoring functional movement and preventing muscle atrophy after spinal cord injury (SCI). Control systems used to optimize delivery of electrical stimulation protocols depend upon mathematical models of paralyzed muscle force outputs. While accurate, the Hill-Huxley-type model is very complex, making it difficult to implement for real-time control. As an alternative, we propose a modified Wiener-Hammerstein system to model the paralyzed skeletal muscle dynamics under electrical stimulus conditions. Experimental data from the soleus muscles of individuals with SCI was used to quantify the model performance. It is shown that the proposed Wiener-Hammerstein system is at least comparable to the Hill-Huxley-type model. On the other hand, the proposed system involves a much smaller number of unknown coefficients. This has substantial advantages in identification algorithm analysis and implementation including computational complexity, convergence and also in real time model implementation for control purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Castro, M. J., Apple Jr, D. F., Hillegass, E. A., & Dudley, G. A. (1999) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050606 · Cited by 383
Cited by
Repetitive Control of Electrical Stimulation for Tremor Suppression
Copur, E. H., Freeman, C. T., Chu, B., & Laila, D. S. (2019) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2017.2771327 · Cited by 38
“Among a variety of models for the latter [26]–[29], a Hammerstein structure will be assumed due to its popularity in the literature [29], confirmed accuracy, structural simplicity, and”
BackgroundAllafi, W., Zajic, I., Uddin, K., & Burnham, K. J. (2017) · IET Control Theory & Applications · doi:10.1049/iet-cta.2017.0284 · Cited by 36
A fractional approach to identify Wiener–Hammerstein systems
Vanbeylen, L. (2014) · Automatica · doi:10.1016/j.automatica.2013.12.013 · Cited by 30
Metadata
- Authors
- Bai, E.-W., Cai, Z., Dudley-Javorosk, S., & Shields, R. K.
- Venue
- Automatica
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 45
- Issue
- 3
- Pages
- 736-743
- ISSN
- 0005-1098 (ISSN-L)
- OpenAlex
- W2119975531
- Cited by
- 74
- References
- 1
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification of a modified Wiener–Hammerstein system and its application in electrically stimulated paralyzed skeletal muscle modeling. https://app.cochat.ai/papers/10.1016/j.automatica.2008.09.023
- The paper
- Bai, E.-W., Cai, Z., Dudley-Javorosk, S., & Shields, R. K. (2009). Identification of a modified Wiener–Hammerstein system and its application in electrically stimulated paralyzed skeletal muscle modeling. Automatica. https://doi.org/10.1016/j.automatica.2008.09.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.