Layer-by-layer microfluidics for biomimetic three-dimensional structures
Abstract
Due to the complex structures of living systems, with size scales spanning from the micron to millimeter range, the use of microtechnology to recreate in vivo-like architecture has exciting potential applications. However, most microscale systems are two-dimensional, and few three-dimensional (3-D) systems are being explored. We have developed a versatile technique, combining surface engineering with layer-by-layer microfluidics technology, to create a 3-D microscale hierarchical tissue-like structure. The process involves immobilization of a cell-matrix assembly, cell-matrix contraction, and pressure-driven microfluidic delivery. An aminopropyltriethoxysilane-glutaraldehyde activated chip is used to effectively immobilize the cell-matrix assemblies while maintaining cell viability. Pressure-driven microfluidics is applied to transport cells-matrices with controlled flow rates, determined from dynamic flow imaging. By taking advantage of the contraction of the biopolymer matrices by cells, layer-by-layer microfluidics can be used to build multilayers of cell-matrix inside a microchannel and the thickness of each layer can be controlled down to microscale dimensions. Confocal and electron microscopy images of the final structure show a hierarchical layered cellular configuration composed of heterogeneous biomimetic materials. For a model system, a biomimetic arterial structure is formed using three types of vascular cells to mimic the 3-tunic structure found in vivo. This approach provides solutions to fabricate hierarchical "neotissues" with controlled microarchitectures and 3-D configurations of multiple cell types.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hydrogel-based 3D systems more accurately mimic 3D tissue architecture, cell proliferation, motility, and migration via an artificial extracellular matrix.
“and more accurately mimic 3D tissue architecture, cell proliferation, motility, and migration via an artificial extracellular matrix. 86”
From Three-dimensional cell culture systems and their applications in drug discovery and cell-based biosensors (2014) · cites this paper as [86]
Collagen, collagen-chitosan, Matrigel, fibrinogen matrices, alginate, Puramatrix scaffolds, and polyethylene glycol matrices have been used to fabricate 3D cell culture biosensors using various cell lines for drug screening, toxicology assays, cell-biomaterial interaction screening, and identification of unknown pathogens and toxins.
“Collagen, collagen-chitosan, Matrigel, and fibrinogen matrices, alginate, Puramatrix scaffolds, and polyethylene glycol matrices have been used to fabricate 3D cell culture biosensors using various cell lines for drug screening, toxicology assays, and cell-biomaterial interaction screening, and for the identification of unknown pathogens and toxins. 80,86,87”
From Three-dimensional cell culture systems and their applications in drug discovery and cell-based biosensors (2014) · cites this paper as [86]
The citation lists haven’t been fetched yet
References 24 · Cited by 193
- Authors
- Tan, W., & Desai, T. A.
- Affiliations
- Boston University (US)
- Corresponding author
- Desai, Tejal A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2004-03
- Volume
- 25
- Issue
- 7-8
- Pages
- 1355-1364
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2094210403
- Cited by
- 193
- References
- 24
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 4 · 2023: 2 · 2022: 6 · 2021: 3 · 2020: 6 · 2019: 6 · 2018: 6 · 2017: 3 · 2016: 3 · 2015: 13 · 2014: 10 · 2013: 12 · 2012: 16
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- 3D tissue engineering, biomimetic structures, 3-aminopropyltriethoxysilane, glutaraldehyde, cell immobilization, arterial structure, surface engineering
- MeSH terms
- Cell Line, Cell Survival, Cells, Cultured, Extracellular Matrix, Fibroblasts, Humans, Materials Testing, Cell Culture Techniques, Coated Materials, Biocompatible, Tissue Engineering, Biomimetic Materials, Endothelial Cells, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review