The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Controlling surface nano-structure using flow-limited field-injection electrostatic spraying (FFESS) of poly(d,l-lactide-co-glycolide)
Abstract
Improved control of surface micro- and nano-structure may lead to enhanced performance of degradable biomedical devices such as surgical dressings, vascular grafts, tissue engineering scaffolds, sutures, and structures for guided tissue regeneration. An electrohydrodynamic method called flow-limited field-injection electrostatic spraying (FFESS) has been developed as an improved technique for the controlled deposition of polymeric material. Injecting charge using a nano-sharpened tungsten needle in a process called field ionization can efficiently induce an ionic state in a solution of poly(D,L-lactide-co-glycolide) increasing its capacity to carry charge. As a result, sprays have been produced that are finer and more precisely controlled than sprays produced by conventional electrospraying techniques, which employ hypodermic needles as the spray nozzle. Here, the effect of FFESS variables including applied voltage, polymer solution flow rate, and solvent properties (surface tension, viscosity, vapor pressure) on spray performance have been qualitatively evaluated. Under certain conditions, increasing the applied voltage produced an increasingly rough surface morphology. Similarly, by reducing solvent surface tension and increasing solvent vapor pressure, more distinct surface structures could be formed including uniform nanoparticles. Working ranges of the important parameters for the production of specific structure types such as smooth or porous surfaces, non-woven or melded fibers, and distinct or melded nanoparticles have been defined. FFESS technology provides a simple yet powerful technique for fabricating biomedical devices with a precisely defined nano-structure potentially capable of utilizing a broad range of biocompatible polymeric materials.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recently, several new methods to manufacture PLGA or PLA particles have been reported, such as the ultrasonic atomization method [14,15], the electrospray method [16], the microfluidic method [17,18], the pore-closing and thermoreversible-gel method [19,20], and the microfabrication method [21].”
From Use of lectin-functionalized particles for oral immunotherapy (2012) · cites this paper as [16]
Citations
Cites
The effect of processing variables on the morphology of electrospun nanofibers and textiles
Deitzel, J. M., Kleinmeyer, J. D., Harris, D., & Tan, N. C. B. (2001) · Polymer · doi:10.1016/s0032-3861(00)00250-0 · Cited by 2,918
Jain, R. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00115-0 · Cited by 2,214
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,873
Experimental characterization of electrospinning: the electrically forced jet and instabilities
Shin, Y.-S., Hohman, M. M., Brenner, M. P., & Rutledge, G. C. (2001) · Polymer · doi:10.1016/s0032-3861(01)00540-7 · Cited by 1,069
Taylor cone and jetting from liquid droplets in electrospinning of nanofibers
Yarin, A. L., Koombhongse, S., & Reneker, D. H. (2001) · Journal of Applied Physics · doi:10.1063/1.1408260 · Cited by 895
Transport properties of porous membranes based on electrospun nanofibers
Gibson, P., Schreuder‐Gibson, H. L., & Rivin, D. (2001) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(01)00616-1 · Cited by 879
Processing and microstructural characterization of porous biocompatible protein polymer thin films
Buchko, C. J., Chen, L. C., Shen, Y. L., & Martin, D. C. (1999) · Polymer · doi:10.1016/s0032-3861(98)00866-0 · Cited by 714
Biodegradable Polymer Scaffolds with Well-Defined Interconnected Spherical Pore Network
Ma, P. X., & Choi, J. (2001) · Tissue Engineering · doi:10.1089/107632701300003269 · Cited by 621
Boland, E. D., Wnek, G. E., SIMPSON, D. L., Pawlowski, K. J., & Bowlin, G. L. (2001) · Journal of Macromolecular Science Part A · doi:10.1081/ma-100108380 · Cited by 464
Murphy, W. L., Peters, M. C., Kohn, D. H., & Mooney, D. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00120-4 · Cited by 413
Flagged first, then by citations
Research works printed but not linked: 1
- Tice, 1984, Biodegradable controlled-release parenteral systems, Pharm Technol, 11, 26
Cited by
Sorted by citations
Items 101–113 of 113
Monodispersed microencapsulation technologies
Dormer, N. H., Berkland, C. J., & Singh, M. K. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821683-5.00015-7 · Cited by 1
Self-citationSaito, S., Takehara, H., & Ichiki, T. (2020) · Journal of Photopolymer Science and Technology · doi:10.2494/photopolymer.33.337 · Cited by 1
Novel electrostatic technologies for functional nanomaterials production
Jaworek, A., Krupa, A., Lackowski, M., Sobczyk, A. T., & Czech, T. (2010) · PRZEGLĄD ELEKTROTECHNICZNY
Engineering Pharmaceutical Nanoparticles
Berkland, C. J. (2006) · KU ScholarWorks (University of Kansas)
Self-citationEffects of High Voltage Prick Electrostatic Field on Lewis
Zhang, Y., & Sun, Y. C. (2004) · Elsevier eBooks · doi:10.1016/b978-008044584-7.50074-8
Electrohydrodynamic Processing of Micro- and Nanometer Biological Materials
Clark, R. L., & Wu, Y. (2008) · CRC Press eBooks · doi:10.1201/9780849379741.ch11
Kaufman, J. D., Wong, J. Y., & Klapperich, C. M. (2007) · CRC Press eBooks · doi:10.1201/9780849378898-10
A NANOFIBER-STRUCTURED BIOPOLYMER FOR ADVANCED DRUG DELIVERY SYSTEMS
박천권 (2014) · Seoul National University Open Repository (Seoul National University)
Chauvel‐Lebret, D., Auroy, P., & Bonnaure‐Mallet, M. (2016) · Taylor & Francis eBooks · doi:10.1081/e-ebpp-120052256
Controlling and Assessing Cell–Biomaterial Interactions at the Micro- and Nanoscale
Klapperich, C. M., Kaufman, J. D., & Wong, J. Y. (2007) · CRC Press eBooks · doi:10.1201/9780849378898.ch10
赵, 勇., 江, 雷., & 陈, 洪. (2009) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/csb2009-54-10-1338
(2007) · Wiley eBooks · doi:10.1002/9780470229842.refs
Forming of novel drug carriers for stimulated encapsulation, storage and release
Chang, M. (2011) · UCL Discovery (University College London)
Metadata
- Authors
- Berkland, C., Pack, D. W., & Kim, K. (.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Kim, Kyekyoon (Kevin)
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2004-11
- Volume
- 25
- Issue
- 25
- Pages
- 5649-5658
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2034161470
- Cited by
- 114
- References
- 44
- Citations by year
- 2025: 2 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 7 · 2019: 6 · 2018: 1 · 2017: 4 · 2016: 2 · 2015: 2 · 2014: 7 · 2013: 4 · 2012: 3
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrohydrodynamics and Fluid Dynamics
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Keywords
- poly(lactic-co-glycolic acid), electrospraying, field ionization, surface morphology control, biodegradable polymers, biomedical devices, nanoparticles, solvent vapor pressure, applied voltage
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Biocompatible Materials, Electricity, Microscopy, Electron, Scanning, Polyglycolic Acid, Polymers, Rheology, Solvents, Surface Properties, Surface Tension, Viscosity, Lactic Acid, Nanotechnology, Nanostructures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review