Fluorescent microparticles for sensing cell microenvironment oxygen levels within 3D scaffolds
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We present the development and characterization of fluorescent oxygen-sensing microparticles designed for measuring oxygen concentration in microenvironments existing within standard cell culture and transparent three-dimensional (3D) cell scaffolds. The microparticle synthesis employs poly(dimethylsiloxane) to encapsulate silica gel particles bound with an oxygen-sensitive luminophore as well as a reference or normalization fluorophore that is insensitive to oxygen. We developed a rapid, automated and non-invasive sensor analysis method based on fluorescence microscopy to measure oxygen concentration in a hydrogel scaffold. We demonstrate that the microparticles are non-cytotoxic and that their response is comparable to that of a traditional dissolved oxygen meter. Microparticle size (5-40 microm) was selected for microscale-mapping of oxygen concentration to allow measurements local to individual cells. Two methods of calibration were evaluated and revealed that the sensor system enables characterization of a range of hypoxic to hyperoxic conditions relevant to cell and tissue biology (i.e., pO(2) 10-160 mmHg). The calibration analysis also revealed that the microparticles have a high fraction of quenched luminophore (0.90+/-0.02), indicating that the reported approach provides significant advantages for sensor performance. This study thus reports a versatile oxygen-sensing technology that enables future correlations of local oxygen concentration with individual cell response in cultured engineered tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cycling hypoxia and free radicals regulate angiogenesis and radiotherapy response
Dewhirst, M. W., Cao, Y., & Moeller, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2397 · Cited by 1,022
Oxygen gradients correlate with cell density and cell viability in engineered cardiac tissue
Radisic, M., Malda, J., Epping, E., Geng, W., Langer, R., & Vunjak‐Novakovic, G. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20722 · Cited by 399
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Barthes, J., Özçelik, H., Hindié, M., Ndreu-Halili, A., Hasan, A., & Vrana, N. E. (2014) · BioMed Research International · doi:10.1155/2014/921905 · Cited by 230
“[165] developed a fluorescent microparticle based oxygen sensing system that enables the monitoring of hypoxia and hyperoxia conditions within the 3D tissue engineering scaffolds.”
BackgroundThe immune reaction and degradation fate of scaffold in cartilage/bone tissue engineering
Yang, D., Xiao, J., Wang, B., Li, L., Kong, X., & Liao, J. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.109927 · Cited by 192
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Metadata
- Authors
- Acosta, M. A., Ymele-Leki, P., Kostov, Y. V., & Leach, J. B.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-06
- Volume
- 30
- Issue
- 17
- Pages
- 3068-3074
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2026552771
- Cited by
- 73
- References
- 2
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent microparticles for sensing cell microenvironment oxygen levels within 3D scaffolds. https://app.cochat.ai/papers/10.1016/j.biomaterials.2009.02.021
- The paper
- Acosta, M. A., Ymele-Leki, P., Kostov, Y. V., & Leach, J. B. (2009). Fluorescent microparticles for sensing cell microenvironment oxygen levels within 3D scaffolds. Biomaterials. https://doi.org/10.1016/j.biomaterials.2009.02.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.